Instructions / Assembly
17
INSTALLATION
ENGLISH
3-Wire Connection: Conduit
Install the conduit as follows:
Remove the conduit connection plate from the rear of 
the oven and rotate it. The conduit hole (1
1
/
8
") must 
be used.
First, prepare the conduit wires as shown below.
3-Wire
Conduit 
connection 
plate
Ground 
wire
or
4-Wire
Second, install the conduit strain relief.
For conduit installations, purchase a strain relief and 
insert it in the 1
1
/
8
 in. (2.8 cm) conduit hole. Then 
install the conduit through the body of the strain relief 
and fasten the strain relief with its ring. Reinstall the 
bracket. 
For conduit connections: 
If the wire in the conduit is copper it must be 8 or 10 
AWG wiring. 
If the wire in the conduit is aluminum it must be 6 or 8 
AWG wiring.
1
Loosen the lower 3 screws from the terminal 
block.
2
Insert the bare wire (white/neutral) end through 
the center terminal block opening. Do not 
remove the ground strap connections.
3
Insert the two side bare wire ends into the lower 
left and the lower right terminal block openings. 
Tighten the 3 screws securely into the terminal 
block. (approximately 35 - 50 IN-LB)
3-wire connection
Terminal 
block
Black White Red
Wire 
ends
Conduit 
connection plate
If screws are not tightened securely, it can result in 
electrical spark and severe personal injury or death.
4-Wire Connection: Conduit
WARNING
•
The white middle (neutral) wire of the power 
cord or 4-wire conduit has to be connected 
to the middle post of the main terminal 
block. The other two wires of the power 
cord or conduit have to be connected to 
the outside posts of the main terminal 
connection block. The 4th ground wire 
(green) must be connected to the frame of 
the range with the ground screw. Failure 
to do so can result in electrical shock, severe 
personal injury or death.
1
Follow the instructions for installing the conduit 
under 3-Wire Connection: Conduit until the strain 
relief and bracket are installed. Do not install the 
conduit without a strain relief.
2
Loosen the 2 lower left and right screws from 
the terminal block. Remove the lower 2 center 
screws. Do not discard any screws.
3
Remove the ground screw and bend the end of 
the ground strap up so the slot is over the hole 
of the center screw removed in step 1.
4
Attach the ground (green) bare wire end to 
the range frame and secure it in place with the 
ground screw.
5
Insert the bare wire (white/neutral) end through the 
center terminal block opening. The center screw 
now attaches the bent up ground strap to the block.
6
Insert the two side bare wire ends into the left 
and the right terminal block openings. Tighten 
the 3 screws securely into the terminal block. 
(approximately 35 - 50 IN-LB)
4-wire connection
Terminal 
block
Black White Red
Ground 
strap
Wire 
ends
Conduit 
connection 
plate
Bend strap 
up and 
attach
Ground 
wire
Ground 
screw
If screws are not tightened securely, it can result in 
electrical spark and severe personal injury or death.