ENGLISH êìëëäàâ üáõä ìäêÄ∫çëúäÄ OWNER’S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : WALL MOUNTED The equipment complies with requirements of the Technical Regulation, in terms of restrictions for the use of certain dangerous substances in electrical and electronic equipment. P/NO : MFL41604515 www.lg.
Room Air Conditioner Ownerʼs Manual TABLE OF CONTENTS A. Safety Precautions ..............................3 FOR YOUR RECORDS B. Electrical Safety...................................6 Temporary Use of an Adapter ...............6 Temporary Use of an Extension Cord ...6 Symbols used in this Manual.................6 Write the model and serial numbers here: C. Product Introduction...........................7 Indoor Units ...........................................7 Operation Indication Lamps ................
Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. ■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage. ■ Meanings of symbols used in this manual are as shown below. Be sure not to do. Be sure to follow the instruction.
Safety Precautions Indoor/outdoor wiring connections must be secured tightly and the cable should be routed properly so that there is no force pulling the cable from the connection terminals. Safely dispose off the packing materials. Like screws, nails, batteries, broken things etc after installation or svc and then tear away and thraw away the plastic packaging bags. Make sure to check that the power cable plug is not dirty, loose or broken and then only insert the plug completely.
Safety Precautions • There is risk of damage or loss of property. Do not touch the metal parts of the product when removing the air filter. • There is risk of personal injury. Do not insert hands or other objects through the air inlet or outlet while the product is operating. • There are sharp and moving parts that could cause personal injury. Do not tilt the unit when removing or uninstalling it. • The condensed water inside can spill .
Electrical Safety Electrical Safety • This appliance must be properly grounded. To minimize the risk of electric shock, you must alway plug into a grounded oulet. • Do not cut or remove the grounding prong from the power plug. • Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the house wiring.
Product Introduction Here is a brief introduction of the indoor and outdoor units. Please see the information specific to your indoor unit type.
Product Introduction Operating Instructions How to insert the Batteries 1. Remove the battery cover by pulling it according to the arrow direction. 2. Insert new batteries making sure that the (+) and (-) of battery are installed correctly. 3. Reattach the cover by sliding it back into position. NOTE 1. Always use/replace both batteries of same type. 2. If the system is not to be used for a long time, remove the batteries to save their working life. 3.
Operating Instructions ENGLISH Remote Control Operation The remote control transmits the signals to the system. TEMP. OFF TIME hr. 1 OPERATION DISPLAY Displays the operation conditions. 2 CHAOS SWING BUTTON Used to stop or start louver movement and set the desired up/down airflow direction. 1 3 4 8 2 7 5 3 OPERATION MODE SELECTION BUTTON Used to select the operation mode. 4 OFF TIMER BUTTON Used to set the time of stopping operation.
Operating Instructions Cooling Operation 1 Press the Start/Stop Button. p , Bee Beep 2 Select Cooling Operation. Press the Operation Mode Selection Button. Each time the button is pressed, the operation mode is shifted in the arrow direction. TEMP. OFF TEMP. TIME Cooling OFF TIME TEMP. OFF hr. hr. TIME TEMP. OFF hr. Healthy Dehumidification TIME hr. Heating (Heat pump model only) TEMP. OFF TIME TEMP. OFF hr. hr.
Operating Instructions ENGLISH Healthy Dehumidification Operation Mode This mode dehumidifies without overcooling. 1 Press the Start/Stop Button. p , Bee Beep 2 Select Healthy Dehumidification Operation. Press the Operation Mode Selection Button. Each time the button is pressed, the operation mode is shifted in the arrow direction. TEMP. OFF OFF TIME hr. TIME TEMP. OFF hr. Cooling TIME TEMP. OFF hr. Healthy Dehumidification TIME hr. Heating (Heat pump model only) TEMP. OFF TIME TEMP.
Operating Instructions Heating Operation(Heat pump model only) 1 Press the Start/Stop button. The unit will respond with a beep. 2 To select Heating Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow. TEMP. OFF TIME hr. TEMP. OFF TIME hr. Cooling 3 TEMP. OFF TIME TEMP. OFF hr. Healthy Dehumidification TIME hr.
Operating Instructions ENGLISH Jet Cool Operation TEMP. OFF TIME 1 Press the Start/Stop button. The unit will respond with a beep. 2 Press the Jet Cool button to operate the speed cooling mode and the unit will operate in super high fan speed on cooling mode for 30 minutes. 3 To cancel the Jet Cool mode, press the Jet Cool button again or the fan speed button or the room temperature setting button and the unit will operate in high fan speed on cooling mode. hr.
Operating Instructions Forced operation Operation procedures when the remote control can't be used. The operation will be started if the ON/OFF button is pressed. If you want to stop operation, re-press the button. Standard type Rational type ON/OFF button Cooling Model Operating mode Indoor FAN Speed Setting Temperature Cooling High 22°C ON/OFF button Room Temp. ≥ 24°C Cooling High 22°C Heat pump Model 21°C ≤ Room Temp. < 24°C Healthy Dehumidification High 23°C Room Temp.
Operating Instructions The up/down airflow (Vertical airflow) can be adjusted by using the remote controller. The left/right(Horizontal airflow) can be adjusted by using the remote control. 1. Press the START/STOP BUTTON to start the unit. 1. Press the START/STOP BUTTON to start the unit. 2. Press CHAOS SWING BUTTON. 2. Press the HORIZONTAL AIRFLOW DIRECTION BUTTON. 3. The louvers will swing up & down automatically. 4. To stop the louver at a desired angle, press again 3.
Maintenance and Service Maintenance and Service Before performing any maintenance, turn off the main power to the system, disconnect the circuit breaker and unplug the power cord. Indoor Unit Clean the unit with a soft dry cloth. Do not use bleach or abrasives. Never use any of these • Water hotter than 40°C. It may cause deformation and discoloration. • Volatile substances. They may damage the surface of the air conditioner.
Maintenance and Service The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam cleaned. NOTE Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs. Operation Tips! Do not overcool the room. Keep blinds or curtains closed. This is not good for the health and wastes electricity.
Maintenance and Service Troubleshooting Tips! Save time and money! The air conditioner may be operating abnormally when: Problem Air conditioner does not start Air conditioner does not cool as it should Possible Causes What To Do ■ The air conditioner is unplugged. • Make sure the air conditioner plug is pushed completely into the outlet. ■ The fuse is blown/circuit breaker is tripped. • Check the house fuse/circuit breaker box and replace the fuse or reset the breaker. ■ Power failure.