Type : Wall Mounted FRANÇAIS DEUTSCH OWNER'S MANUAL ESPAÑOL LG Air Conditioner ITALIANO LG ENGLISH Visit us at http://www.lgservice.com ∂§§∏¡πÃÕ PORTUGUÊS NEDERLANDS MAGYAR • Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner. • Please retain this owner's manual for future reference after reading it thoroughly.
Air Conditioner Owner’s Manual TABLE OF CONTENTS A. Safety Precautions ..............................3 B. Electrical Safety...................................6 Temporary Use of an Adapter ...............6 Temporary Use of an Extension Cord ...6 Symbols used in this Manual.................6 C. Product Introduction...........................7 Indoor Units ...........................................7 Operation Indication Lamps ..................7 Self-Diagnosis Function ........................7 D.
Safety Precautions Safety Precautions This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage. ■ Meanings of symbols used in this manual are as shown below. Be sure not to do. Be sure to follow the instruction. Always use a power plug and socket with a ground terminal. • There is a risk of electrical shock. For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center.
Safety Precautions Indoor/outdoor wiring connections must be secured tightly and the cable should be routed properly so that there is no force pulling the cable from the connection terminals. Safely dispose off the packing materials. Like screws, nails, batteries, broken things etc after installation or svc and then tear away and thraw away the plastic packaging bags. Make sure to check that the power cable plug is not dirty, loose or broken and then only insert the plug completely.
Safety Precautions Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system. • There is a risk of damage or loss of property. • There is a risk of personal injury. Do not insert hands or other objects through the air inlet or outlet while the product is operating. • There are sharp and moving parts that could cause personal injury. Do not tilt the unit when removing or uninstalling it.
Electrical Safety Electrical Safety • This appliance must be properly grounded. To minimize the risk of an electrical shock, you must always plug into a grounded outlet. • Do not cut or remove the grounded prong from the power plug. • Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the house wiring.
Product Introduction Product Introduction Here is a brief introduction of the indoor and outdoor units. Please see the information specific to your indoor unit type.
Operating Instructions Operating Instructions How to insert the Batteries 1. Remove the battery cover by pulling it according to the arrow direction. 2. Insert new batteries making sure that the (+) and (-) of battery are installed correctly. 3. Reattach the cover by sliding it back into position. NOTE 1. Always use/replace both batteries of same type. 2. If the system is not to be used for a long time, remove the batteries to save their working life. 3.
Operating Instructions Wireless Remote Controller The controls will look like the following. CANCEL ON OFF SET AUTO CLEAN CANCEL SET Flip-up door (opened) ENERGY-SAVING COOLING MODE BUTTON Operation Mode ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature. RESET BUTTON Used prior to resetting time. 2nd F BUTTON Used prior to using modes printed in blue at the bottom of buttons.
Operating Instructions Operation Mode 1 3 1 Press the START/STOP BUTTON to turn the unit on. The unit will respond with a beep. 2 Open the door of the remote controller and press the operation mode button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
Operating Instructions Healthy Dehumidification Operation To run the healthy dehumidification mode follow steps 1, and 2 and 4 (See operation mode) Auto Operation (Optional) In this operation the actual operating mode is automatically set by the electronic control logic based on the current room temperature or other connected indoor unit. If you feel hot or cold, you can set the temperature or fan speed for more cooling or heating effect. Setting Temp.
Operating Instructions Jet Cool/Heat Operation Jet Cool function can be used to cool the room quickly in hot summer. When this function is turned on, the air conditioner runs in cooling operation mode with super high fan speed and 18°C setting temperature for 30 minutes for fast and effective cooling. Similarly,Jet Heat function (available only in some models) warms up the room quickly by operating at super high fan speed and 30°C setting temperature for 30 minutes.
Operating Instructions Energy-Saving Cooling Mode (Optional) 1. Press the START/STOP BUTTON to start the unit. 2. Open the door on the remote controller. Select cooling operation. 3. Press the ENERGY-SAVING COOLING MODE BUTTON. 4. To cancel the energy-saving cooling mode, press the ENERGY-SAVING COOLING MODEL BUTTON AGAIN AND UNIT WILL OPERATE IN COOLING MODE. Display Luminosity The Display Luminosity can be adjusted by using the remote control. Press the start/stop button to start the unit.
Operating Instructions Sleep Mode 1. Press the SLEEP MODE AUTO BUTTON to set the time when you want the unit to stop automatically. 2. The timer is programmed in one-hour increments by pressing the SLEEP MODE AUTO BUTTON 1 to 7 times. The sleep mode is available for 1 to 7 times. To alter the time period in steps of 1 hour, press the SLEEP MODE AUTO BUTTON while aiming at air conditioner.
Operating Instructions Vertical / Horizontal Airflow Direction Control The up/down airflow (Vertical airflow) can be adjusted by using the remote controller. 2. Press CHAOS SWING BUTTON. 3. The louvers will swing left & right automatically. 3. The louvers will swing up & down automatically. 4. To stop the louver at a desired angle, press again 4. To stop the louvers at a desired angle, press again.
Wired Remote Controller (Accessory) MODEL : PQRCVSA0 1 2 3 4 5 1 10 9 8 2 3 7 4 11 12 13 FAN SPEED BUTTON ON/OFF BUTTON OPRATION MODE SELECTION BUTTON RECEIVER • Some products don't receive the wireless signals. 6 7 8 9 10 15 SET TEMPERATURE BUTTON 6 WIRELESS REMOTE CONTROLLER 5 14 OPERATION INDICATION SCREEN AIR FLOW BUTTON SUBFUNCTION BUTTON FUNCTION SETTING BUTTON VENTILATION BUTTON 11 RESERVATION 12 UP,DOWN,LEFT,RIGHT BUTTON Please attach the inform label inside of the door.
Maintenance and Service Maintenance and Service Clean the unit with a soft dry cloth. Do not use bleach or abrasives. Never use any of these • Water hotter than 40°C. It may cause deformation and discoloration. • Volatile substances. They may damage the surface of the air conditioner. Pow d er G a s o li n e Air Filters The air filters behind the front panel / grill should be checked and cleaned once in every 2 weeks or more often if necessary.
Maintenance and Service Outdoor Unit The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam cleaned. NOTE Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs. Operation Tips! Do not overcool the room. This is not good for the health and wastes electricity. Make sure that the doors and windows are shut tight.
Maintenance and Service Troubleshooting Tips! Save time and money! The air conditioner may be operating abnormally when: Air conditioner does not start Air conditioner does not cool as it should Possible Causes What To Do ■ The air conditioner is unplugged. • Make sure the air conditioner plug is pushed completely into the outlet. ■ The fuse is blown/circuit breaker is tripped. • Check the house fuse/circuit breaker box and replace the fuse or reset the breaker. ■ Power failure.
Air Conditioner
P/No.: MFL63265201 Printed in Korea After reading this manual, keep it in a place easily accessible to the user for future reference.