website http://www.lgservice.com ITALIANO LG Room Air Conditioner OWNER'S MANUAL Prior to installation, this airconditioning unit must be submitted for approval by the utility service which provides electricity (EN 61000-3 Norm). ESPAÑOL MODELS: AS - W096_Series W126_Series C09AW_Series C12AW_Series C18AW_Series C24AW_Series ENGLISH LG FRANÇAIS DEUTSCH • Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner.
Room Air Conditioner Owner’s Manual TABLE OF CONTENTS Safety Precautions.........................3 FOR YOUR RECORDS Write the model and serial numbers here: Model # Prior to Operation ..........................6 Serial # You can find them on a label on the side of each unit. Dealer's Name Introduction ....................................7 Electrical Safety .............................8 Operating Instructions.................10 Maintenance and Service ............
Safety Precautions Safety Precautions This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to properties only. ■ The meanings of the symbols used in this manual are as shown below. Be sure not to do. Be sure to follow the instruction. ■ Installation Always perform grounding. • Otherwise, it may cause electrical shock. Securely attach the electrical part cover to the indoor unit and the service panel to the outdoor unit.
Safety Precautions ■ Operation Do not share the outlet with other appliances. Do not use the damaged power cord. • It will cause an electric shock or a fire due to heat generation. • Otherwise, it may cause a fire or electrical shock. Take care so that the power cord may not be pulled during operation. Unplug the unit if strange sounds, smell, or smoke comes from it. • Otherwise, it may cause a fire or electrical shock.
Safety Precautions ■ Installation • Otherwise, it may cause water leakage. Always inspect gas leakage after the installation and repair of product. • Otherwise, it may cause the failure of product. Install the product so that the noise or hot wind from the outdoor unit may not cause any damage to the neighbors. • Otherwise, it may cause dispute with the neighbors. Keep level parallel in installing the product. • Otherwise, it may cause vibration or water leakage.
Prior to Operation Prior to Operation Preparing for Operation 1. Contact an installation specialist for installation. 2. Plug in the power plug properly. 3. Use a dedicated circuit. 4. Do not use an extension cord. 5. Do not start/stop operation by plugging/unplugging the power cord. 6. If the cord/plug is damaged, replace it with only an authorized replacement part. Usage 1. Being exposed to direct airflow for a long time may be hazardous to your health.
Introduction Introduction Symbols used in this Manual This symbol alerts you to hazards that may cause harm to the air conditioner. NOTICE This symbol indicates special notes. Features WARNING: This appliance should be installed in accordance with national wiring regulations. This guide acts as a guide to help to explain product features.
Electrical Safety Electrical Safety WARNING: This appliance must be properly grounded. To minimize the risk of electric shock, you must alway plug into a grounded oulet. Preferred method Ensure proper ground exists before use WARNING: Do not cut or remove the grounding prong from the power plug.
Electrical Safety Temporary Use of an Adapter Temporary method Adapter Plug Metal Screw Receptacle Cover WARNING: Never use the appliance with a broken adapter. Temporary Use of an Extension Cord We strongly discourage the use of an extension cord due to potential safety hazards. For temporary situations, use only CSA certified and UL listed 3-wire grounded extension cords, rated 15 A, 125 V. Owner's Manual 9 ENGLISH We strongly discourage the use of an adapter due to potential safety hazards.
Operating Instructions Operating Instructions Remote Controller 1. Remove the battery cover by pulling it according to the arrow direction. 2. Insert new batteries making sure that the (+) and (-) of battery are installed correctly. 3. Reattach the cover by sliding it back into position. NOTICE Use 2 AAA(1.5volt) batteries. Do not use rechargeable batteries. Storage and Tips for using the Remote Controller • The remote controller may be stored by mounting it on a wall.
Operating Instructions Remote Control Operations The controls will look like the following. 1. START/STOP BUTTON Operation starts when this button is pressed and stops when the button is pressed again. 2. OPERATION MODE SELECTION BUTTON Used to select the operation mode. 3. ROOM TEMPERATURE SETTING BUTTONS Used to select the room temperature. 4. INDOOR FAN SPEED SELECTOR Used to select fan speed in four steps low, medium, high and CHAOS. 5 5.
Operating Instructions Cooling operation 1 Press the Start/Stop button. The unit will respond with a beep. 2 Open the door on the remote control. To select Cooling Operation or Healthy Dehumidification Operation. Cooling 3 ON Auto changeover Healthy Dehumidification Heating (Heat pump model only) Press the Jet Cool button to operate the speed cooling mode and the unit will operate in super high fan speed on cooling mode for 30 minutes.
Operating Instructions Auto changeover operation ENGLISH 1 Press the Start/Stop button. The unit will respond with a beep. 2 Open the door of the remote controller. To select Auto Changeover Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow. Cooling 3 Auto changeover Healthy Dehumidification Heating (Heat pump model only) Close the door of the remote controller.
Operating Instructions Auto operation (Optional) 1 Press the Start/Stop button. The unit will respond with a beep. 2 Open the door of the remote controller. To select Auto Operation, press the operation mode selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
Operating Instructions Healthy dehumidification operation Press the Start/Stop button. The unit will respond with a beep. 2 Open the door of the remote controller. To select Healthy Dehumidification Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
Operating Instructions Heating operation (Heat pump model only) 1 Press the Start/Stop button. The unit will respond with a beep. 2 Open the door of the remote controller. To select Heating Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow. Cooling 3 ON Auto changeover Healthy Dehumidification Heating (Heat pump model only) Close the door of the remote controller.
Operating Instructions Jet cool operation ENGLISH 1 Press the Start/Stop button. The unit will respond with a beep. 2 Press the Jet Cool button to operate the speed cooling mode and the unit will operate at super high fan speed on cooling mode for 30 minutes.
Operating Instructions Jet heat operation (Optional) 1 Press the Start/Stop button. The unit will respond with a beep. 2 Open the door of the remote controller. To select Heating Operation. Cooling Auto changeover Healthy Dehumidification Heating (Heat pump model only) 3 Press the Jet Heat button to operate the speed heating mode and the unit will operate at super high fan speed on heating mode for 60 minutes.
Operating Instructions PLASMA purification operation(Optional) ENGLISH 1 Press the Start/Stop button. The unit will respond with a beep. 2 Open the door of the remote controller. Press the PLASMA button. Operation will start when the button is pressed and stop when the button is pressed again. 3 Set the fan speed again with the door of the remote controller closed. You can select the fan speed in four steps-low, medium, high or CHAOS. Each time the button is pressed, the fan speed mode is shifted.
Operating Instructions 2nd F operation 1 Press the Start/Stop button. The unit will respond with a beep. 2 Open the door of the remote control and press the 2nd Function button to operate functions printed in blue unter buttons. (Check the indication of 2nd function on the display of the remote controller.) These buttons can set the timer as follows: ON OFF SET CANCEL ON OFF SET AUTO CLEAN 3 2nd function disappears in a short time automatically or when the button is pressed again.
Operating Instructions Additional Features Sleep mode 2. The Timer is programmed in one-hour increments by pressing the Sleep Mode Auto button 1 to 7 times. The sleep mode is available for 1 to 7 times. To alter the time period in steps of 1 hour, press the Sleep Mode Button while aiming at air conditioner. 3. Make sure the Sleep Mode Auto LED lights up. To cancel the Sleep Mode, press the sleep Mode Auto button several times until the star ( ) disappears from the operation display.
Operating Instructions Vertical Airflow Direction Control The up/down airflow (Vertical Airflow) can be adjusted by using the remote control. 1. Press the Start/Stop button to start the unit. 2. Press Chaos Swing button and the louvers will swing up and down. Press the Chaos Swing button again to set the vertical louver at the desired airflow direction.
Operating Instructions Auto clean(Optional) NOTICE This function is to remove unpleasant smells from mold and other bacteria in the air-conditioner, and to remove humidity automatically during humidly summer, which supplies the indoor with purified air. Forced operation Operation procedures when the remote control can't be used. The operation will be started if the power button is pressed. If you want to stop operation, re-press the button.
Maintenance and Service Maintenance and Service Indoor Unit WARNING: Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives. NOTICE Supply power must be disconnected before cleaning the indoor unit. 1. Open the upside of Front Panel Front panel 2. Put up the Front panel. The hook of panel comes off. Panel hook 3. Come down the panel and then remove the air filter.
Maintenance and Service Outdoor Unit NOTICE Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs. (Rear) Air intake vents (Side) Piping Drain Hose Air outlet vents (Rear) Air intake vents (Rear) (Side) Piping Drain Hose Air outlet vents Air intake vents (Side) Piping Drain Hose Air outlet vents Cleaning Filter • Recomended use period : About 3 months 1. Open the upside of Front panel. 2. Put up the front panel.
Maintenance and Service When the air conditioner is not going to be used for a long time. When air conditioner is not going to be used for a long time. When the air conditioner is to be used again. Operate the air conditioner on mode for 2 to 3 hours. Clean the air filter and install it in the indoor unit. (Refer to page 24 for cleaning filters.) • This will dry out the internal mechanisms. Turn off the circuit breaker, and disconnect the plug.
Maintenance and Service Troubleshooting Check the following points before requesting repairs or service.... If the fault persists, please contact your dealer or service center. Explanation See page The air conditioner does not operate. • Have you made a mistake in timer operation? • Has the fuse blown or has the circuit breaker been tripped? 21 - The room has a peculiar odor. • Check that this is not a damp smell exuded by the walls, carpet, furniture, or cloth items in the room.
Memo 28 Room Air Conditioner
P/No.: 3828A20283D(Inverter-Series) Printed in Korea After reading this manual, keep it in a place easily accessible to the user for future reference.