29. Fan Fault check (Command: d w)
TochecktheFanfaultoftheSet.
Transmission
[d][w][][SetID][][Data][x]
*ThedataisalwaysFF(inHex).
Dataff:ReadStatus
Acknowledgement
[w][][SetID][][OK/NG][Data][x]
*DataisthestatusvalueoftheFanfault.
Data00:Fanfault
01:FanOk
02:N/A(NotAvaliable)
30. Elapsed time return (Command: d l)
Toreadtheelapsedtime.
Transmission
[d][l][][SetID][][Data][x]
*ThedataisalwaysFF(inHex).
Acknowledgement
[l][][SetID][][OK/NG][Data][x]
*ThedataisalwaysFF(inHex).
(Hexadecimalcode)
31. Temperature value (Command: d n)
Toreadtheinsidetemperaturevalue.
Transmission
[d][n][][SetID][][Data][x]
*ThedataisalwaysFF(inHex).
Acknowledgement
[n][][SetID][][OK/NG][Data][x]
*Thedatais1bytelonginHexadecimal.
32. Lamp fault Check (Command: d p)
Tochecklampfault.
Transmission
[d][p][][SetID][][Data][x]
*ThedataisalwaysFF(inHex).
Acknowledgement
[p][][SetID][][OK/NG][Data][x]
*Thedatais1bytelonginHexadecimal.
Data00:LampFault
01:LampOk
02:N/A(DPM/PowerOff)
33. Auto volume (Command: d u)
Automaticallyadjustthevolumelevel.
Transmission
[d][u][][SetID][][Data][x]
Data00:Off Data01:On
Acknowledgement
[u][][SetID][][OK/NG][Data][x]
34. Speaker (Command: d v)
Turnthespeakeronoroff.
Transmission
[d][v][][SetID][][Data][x]
Data00:Off Data01:On
Acknowledgement
[v][][SetID][][OK/NG][Data][x