U S ER M ANUAL Hybrid Ultrasonic Humidifier Model: LV600HH Questions or Concerns? Please contact us Mon–Fri, 9:00 am–5:00 pm PST/PDT at support@levoit.com or at (888) 726-8520.
Thank you for purchasing the LV 6 0 0 H H H Y B R I D U LT R A S O N I C H U M I D I F I E R BY L E V O I T. If you have any questions or concerns, please reach out to us at support@levoit.com. We hope you enjoy your new humidifier! Share the Levoit Love Find @LevoitLifestyle on social media for wellness + style inspiration. We make every space mindful and chic.
Package Contents Table of Contents Package Contents Specifications Safety Information Getting to Know Your Humidifier Controls Getting Started Using Your Humidifier Preventing Water Leaks Keeping Things Clean Troubleshooting Warranty Information Customer Support 3 3 4 6 8 9 10 14 15 18 21 22 1 1 1 3 3 1 1 x x x x x x x Hybrid Ultrasonic Humidifier Remote Control 3V CR2025 Battery (Pre-Installed) Aroma Pads (1 Pre-Installed) Absorption Pads (1 Pre-Installed) Cleaning Brush User Manual Specifications Po
S A F E T Y I N F O R M AT I O N To reduce the risk of fire, electric shock, or other injury, follow all instructions and safety guidelines. General Safety 4 • Only use the humidifier as described in this manual. • Place the humidifier and cord so that the humidifier will not be knocked over. • When not in use, turn the humidifier off and disconnect from power source by removing the plug from the outlet. • Do not overfill the water tank, as this may cause electric shock.
Power and Cord • Do not handle the power cord or plug with wet hands. Keep the plug and power cord away from liquids. • This humidifier has a polarized plug (one prong is wider than the other), which fits into a polarized outlet only one way. This is a safety feature to reduce the risk of electric shock. If the plug does not fit, reverse the plug. If it still does not fit, do not use the plug in that outlet. Do not bypass this safety feature. Not for commercial use. Household use only.
G E T T I N G TO K N O W YO U R H U M I D I F I E R Function Diagram A. B. C. D. E. F. G. H. I. J. K. L. M. N. O. P. Q. R. S. T.
GETTING TO KNOW YOUR HUMIDIFIER (CONT.) Display Control Panel A. B. C. D. E. F. G. H. I. J. K. L. M. N.
CONTROLS Note: The same controls are also on the included remote control. On/Off Button • Turns the humidifier on/off. Timer Button • Sets or cancels a timer (see page 12). Mist Level Button • Cycles through mist level settings: low, medium, and high. Auto Mode Button • Turns Auto Mode on or off (see page 12). Warm Mist Button • Turns on warm mist and cycles through warm mist settings: low, medium and high heat (see page 11). Humidity Level Button • Sets the Relative Humidity (RH) percentage.
G E T T I N G S TA R T E D 1. Place the humidifier on a flat, level, elevated, and water-resistant surface, such as a table or nightstand. Make sure the room is well-ventilated. Direct the nozzles away from walls and appliances. 12 in / 30 cm Note: • • Position the humidifier at least 12 in / 30 cm away from walls and appliances to prevent them from getting wet. [Figure 2.1] 12 in / 30 cm Do not place the humidifier directly on floors, carpets, or rugs. 2. Remove the nozzle cap from the water tank.
GETTING STARTED (CONT.) 5. Replace the water tank cap. Twist the cap clockwise to secure it tightly to the water tank. [Figure 2.4] Wipe off any excess water on the top and bottom of the base. 6. Carefully place the water tank back onto the base, aligning the water tank cap with the inner chamber. Place the nozzle cap back on top of the water tank. [Figure 2.5] 7. Plug in the humidifier. The humidifier will light up, then turn off. U S I N G YO U R HUMIDIFIER General Operation 1.
USING YOUR HUMIDIFIER (CONT.) Warm Mist Humidity Level • Press to turn on warm mist. Keep pressing to increase the heat setting for the mist, and to turn warm mist off. You can customize the humidity level that the humidifier will maintain. • Caution: Mist may be hot. Do not place your bare hands, face, or other exposed skin over the nozzles while using warm mist. • The humidifier may take 15 minutes to warm up before producing warm mist. • The warm mist function can be used with Auto Mode. 1.
USING YOUR HUMIDIFIER (CONT.) Timer Memory Function You can set a timer between 1 and 12 hours. While the humidifier is plugged in, it will remember your settings (except Timer) when turned off, and will resume these settings when turned back on. • Press repeatedly to choose a time in increments of 1 hour. When you stop pressing , the display will flash 3 times and the timer will start. • The humidifier will automatically power off once the timer is finished.
USING YOUR HUMIDIFIER (CONT.) Using the Aroma Box The humidifier can be used as an aroma diffuser. 1. Turn off the humidifier. 2. Pull out the aroma box on the left side of the humidifier. [Figures 4.1] 3. Put 2-3 drops of essential oil on the aroma pad. [Figure 4.2] 4. Place the aroma box back into the humidifier. Fill the water tank with water and place it back on the base (see Getting Started, page 9). Figure 4.1 5. Plug in and turn on the humidifier.
P R E V E N T I N G WAT E R LEAKS The water tank may leak if not placed properly on the base. • Make sure the silicone ring around the water tank cap is secured at all times. [Figure 5.1] • Twist and secure the cap tightly onto the water tank. [Figure 5.2] Figure 5.1 Note: A small gap between the cap and the tank is normal. • Before moving the humidifier, remove the tank from the base and empty any excess water from the inner chamber. • Wipe off any excess water on the top and bottom of the base.
KEEPING THINGS CLEAN Note: • Always make sure the humidifier is unplugged before cleaning. • Use a tissue or cloth to clean the nozzle regularly. • Do not use liquid detergents to clean the humidifier. • We recommend using purified or distilled water instead of tap water for misting to prevent scale buildup in the humidifier. General Cleaning You should clean the humidifier every 3 days. Change the water every day or every other day to avoid bacteria growth. 1. Unplug the humidifier.
KEEPING THINGS CLEAN (CONT.) Cleaning the Aroma Pad 8. Use the included cleaning brush to remove any scale buildup inside the water tank or in the inner chamber. [Figure 6.3] 1. 9. Pour out the vinegar from the water tank and the inner chamber and thoroughly rinse with warm water. 10. Dry all parts with a clean, dry cloth. Make sure all parts of the humidifier are completely dry before reassembling or storing. 11. Do not use the humidifier immediately after disinfecting. This may be a health hazard.
KEEPING THINGS CLEAN (CONT.) Replacing the Aroma Pads and Absorption Pads If the aroma pads or absorption pads are stiff even after cleaning, then they need to be replaced. Extra pads are included with the humidifier. To maintain the performance of your humidifier, only use official Levoit aroma pads and absorption pads. To buy replacement pads, visit Levoit’s online store. Go to levoit.com for more information. Replacing the Remote Control Battery 1.
T R O U B L E S H O OT I N G Problem Possible Solution No mist comes out of the nozzles. Plug in the humidifier and turn it on. Add at least 2 US cups / 475 mL of purified or distilled water to the water tank. Clean the humidifier (see Keeping Things Clean, page 15). Water may be in the air vent. Take the water tank off and allow the vent to fully air dry before using again. Only a small amount of mist comes out of the nozzles.
TROUBLESHOOTING (CONT.) Problem Possible Solution White dust appears around or in the humidifier. This is caused by minerals in the water. Use purified or distilled water to fill the humidifier. Avoid using water with high mineral content. Clean the humidifier every 3 days (see Keeping Things Clean, page 15). The area around the humidifier is damp or wet. Run the humidifier on a lower mist setting.
TROUBLESHOOTING (CONT.) Problem Possible Solution Incorrect humidity percentage is displayed. The room may be larger than the humidifier’s effective range. Move to a room smaller than 430–753 ft² / 40–70 m². Moisture may have built up inside of the humidity sensor. Turn off the humidifier and allow the sensor to air dry. Make sure the nozzles are facing away from the sensor.
WA R R A N T Y I N F O R M AT I O N Product Name Model Default Warranty Period Hybrid Ultrasonic Humidifier LV600HH 1 year For your own reference, we strongly recommend that you record your order ID and date of purchase. Date of Purchase Order ID Terms & Policy Arovast Corporation warrants all products to be of the highest quality in material, craftsmanship, and service, effective from the date of purchase to the end of the warranty period.
C U S TO M E R S U P P O R T If you have any questions or concerns about your new product, please contact our helpful Customer Support Team. Customer Support Arovast Corporation 1202 N. Miller St., Suite A Anaheim, CA 92806 Email: support@levoit.com Toll-Free: (888) 726-8520 Support Hours Mon–Fri, 9:00 am–5:00 pm PST/PDT *Please have your order invoice and order ID ready before contacting Customer Support.
Connect with us @LevoitLifestyle 23
levoit.com JJ0919AL-M1.