Instruction Manual
SQL3 CMSC INST REV0622
CONTECH LIGHTING
|
725 LANDWEHR ROAD
|
NORTHBROOK, ILLINOIS 60062
|
PHONE 847.559.5500
|
www.contechlighting.com
©2022 Conservation Technology of Illinois, LLC. All rights reserved. Note: Specifications subject to change without notice.
All specifications subject to change without notice. For ConTech’s limited product warranty, go to www.contechlighting.com. For a printed copy of the warranty, call 1-847-559-5500.
INSTALLATION INSTRUCTIONS | SQL3 Series Indoor Square Cylinders:
Surface Mount with Conduit Feed Box
The important safeguards and instructions in this manual are not meant to cover all possible conditions and situations that may occur.
Note: Before attempting installation, please refer to your local electrical code.
P2
Electrical Connections:
• Green/Ground
• White/Neutral
• Black (Line)/Hot
0-10V Dimming Wires:
• Purple/Positive (+)
• Pink or Gray/Negative (–)
INSTALLATION CONTINUED
•
Ensure 3/4 inch EMT Conduit is completely deburred and insert
into desired entry points. EMT Conduit should be fully seated
against built in Stop Block.
•
Tighten Outer Conduit Strap Screws, alternating to maintain
even pressure.
• Tighten Center Set Screw to fully secure Conduit.
•
Clip Cylinder Tether to Conduit Feed Box Tether to assist in wiring.
•
Attach Black Line/Hot Wire to Black Wire, White/Neutral Wire to
White Wire and Green/Ground Wire to Green Wire with Wire Nuts
FOR 0
-
10V DIMMING:
Attach Purple Wire of LED Driver to DIM (
+
) with Wire Nut and
Pink/Gray Wire of LED Driver to DIM (
–
) with Wire Nuts. If not
dimming, use wire connectors to cap these wires individually.
• Carefully feed any excess wire into Conduit Feed Box to avoid
pinching wires.
FIGURE 3 FIGURE 4
• Re-attach cCylinder to Conduit Feed Box by sliding into position
and installing the four (4) screws provided. Tighten evenly to
ensure Cylinder remains aligned.
FIGURE 5
Center Conduit
Set Screw
Outer Conduit
Strap Screw
Stop Block
EMT Conduit
Tether