Install Instructions

POP-UP RECEPTACLE
Cat. Nos. PFUS1, PFUS2, PFTR1, PFTR2, PFGF1, PFGF2
INSTALLATION INSTRUCTIONS ENGLISH
DI-000-PFXXX-05B
WARNINGS
TO AVOID FIRE, SHOCK OR DEATH, TURN OFF POWER AT CIRCUIT BREAKER
OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING!
• TO AVOID RISK OF ELECTRIC SHOCK, ALL NON-GFCI RECEPTACLES MUST BE
GFCI PROTECTED.
IF WATER ENTERS THE ASSEMBLY, TURN POWER OFF AT THE CIRCUIT
BREAKER and replace the unit immediately.
CAUTIONS
• Install and/or use in accordance with appropriate electrical codes and regulations.
• Use only the electrical mounting box provided.
• Use indoors only. Not for use in wet locations, such as kitchen or bathroom countertops.
• For surfaces greater than 2 1/4" thick. (5.72 cm), use the overmount installation.
• If you are unsure about any part of these instructions, consult an electrician.
• Use this device with copper or copper clad wire only.
Includes:
mounting brackets (2)
and screws (4)
protective cover and
screws (2)
Box 26mm screws (2)
Also includes one of the following assembly lids
RESET
RESET
TEST
TEST
Before you install the pop-up receptacle
• Check under flooring to make sure there is enough clearance to accommodate the
box assembly.
• Choose a mounting site where the top of the surface is smooth and free of dirt and
surface irregularities.
• If there are surface irregularities, consider using a flexible sealant between
mounting surface and pop-up assembly.
Installation
1. Choose template and installation method
• For floors with access underneath, use undermount installation (See Template A), included.
• For surfaces greater than 2 1/4" thick. (5.72 cm), use the overmount installation (See Template B), included.
• For concrete installation, cut finished flooring to the size of the box.
2a. Undermount Installation of Box
• Use Template A to cut opening.
• Remove the knockouts furthest from the front of the
box. Pull the conductors through, leaving 6" (15.2 cm)
inside of the box.
• Secure mounting brackets to underside of flooring
using appropriate screws (not provided).
NOTE: 1/8" to 1/4"
below nished
ooring.
2b. Overmount Installation of Box
• Use Template B. Rout the hatched areas 3/16" deep
in the subflooring.
• Remove the knockouts furthest from the front of the
box. Pull the conductors through, leaving 6" (15.2 cm)
inside of the box.
• Secure mounting brackets to routed area using
appropriate screws (not provided).
• Install finished flooring. NOTE: When finished
flooring is installed, the box should be 1/8" to 1/4"
below the surface of the finished flooring.
Suboor
NOTE: 1/8" to 1/4"
below nished ooring.
Suboor
Finished Flooring
Pop-Up Assembly with
Tamper Resistant
Self-Test GFCI
Cat. No.
PFGF1
Cat. No.
PFGF2
15A-125V 20A-125V
Pop-Up Assembly
with Tamper Resistant
Receptacle
Cat. No.
PFTR1
Cat. No.
PFTR2
15A-125V 20A-125V
Pop-Up Assembly with
Duplex USB Charger/
Tamper Resistant
Receptacle
Cat. No.
PFUS1
Cat. No.
PFUS2
15A-125V 20A-125V