leviton specification submittal
JOB NAME: CATALOG NUMBERS:
JOB NUMBER:
cat. no. Description
N0501-000 Protocol Converter and Auto Sequence Control Device. DMX512, LUMA-NET, RS232, MIDI & 0-10V
N0501-001 Protocol Converter and Auto Sequence Control Device. CMX to DMX
N0501-002 Protocol Converter and Auto Sequence Control Device. MPX/DMX to CMX
N0501-003 Protocol Converter and Auto Sequence Control Device. AMX to DMX
N0501-004 Protocol Converter and Auto Sequence Control Device. AMX Output Only
CONVERSION CAPABILITIES
• Micro-plex converts to DMX512
• Micro-plex converts to AMX192
• DMX512 converts to Micro-Plex
• DMX512 converts to AMX192
• MIDI converts to Micro-Plex
• MIDI converts to DMX512
• MIDI converts to AMX192
• RS-232 converts to Micro-Plex
• RS-232 converts to DMX512
• RS-232 converts to AMX192
• 4 Channels 0-10V Analog converts to Micro-Plex
• 4 Channels 0-10V Analog converts to DMX512
• 4 Channels 0-10V Analog converts to AMX192
COMBINE AND CONVERT CAPABILITIES
• Micro-Plex and Luma-Net® convert to Micro-Plex
• Micro-Plex and Luma-Net® convert to DMX512
• Micro-Plex and Luma-Net® convert to AMX192
• DMX512 and Luma-Net convert to Micro-Plex
• DMX512 and Luma-Net convert to DMX512
• DMX512 and Luma-Net convert to AMX192
• Micro-Plex or DMX512 and 4 Channels 0-10V
convert to Micro-Plex
• Micro-Plex or DMX512 and 4 Channels 0-10V
convert to DMX512
• Micro-Plex or DMX512 and 4 Channels 0-10V
convert to AMX192
IF 501 Control Interface
FEATURES
• 8 Pre-programmed auto sequence chases for
stand-alone operation
• Programmable 20 cue sequence ASCII text files
control 16 channels for stand-alone operation
• Interface between a computer and the Luma-Net
network for programming Luma-Net stations
• Trigger Luma-Net pre-sets with external contact
closures
PORTS
• Micro-Plex in (3 pin XLR male)
• Micro-Plex out (3 pin XLR female)
• DMX512 in (5 pin XLR male)
• DMX512 out (5 pin XLR female)
• Optional AMX192 out (4 pin XLR male)
• RS-232 (9 pin D-Sub/DB9 male)
• MIDI in/0-10V analog in (5 pin DIN, 180 degree)
• Luma-Net (RJ14)