FAQ
19
Available in 15 or 20 Amp, 125 volt, features self-test 
circuitry and slim design. For Residential/Commercial 
applications, back and side wired.
• Weather-resistant with stainless steel 
  strap and screws, cold impact resistant 
  face and button
• SAFE — Delivers continuous ground 
  fault protection
• SELF TESTING — Automatically self-tests 
  to ensure it can respond to ground fault
• SIMPLE — Status indicator light 
  provides simple, intuitive feedback
Material taken from the National Electric Code
®
 is reprinted with permission 
from NFPA 70
®
, 2023 edition. National Electrical Code
®
, Copyright 2022, 
National Fire Protection Association, Quincy, MA. All rights reserved.
New
210.8(D)  GFCI Protection for 
Specific Appliances 
Change Summary 
• GFCI protection is required for the branch circuit or   
  outlets supplying appliances. The appliances are put 
  in list format.
  NEC
®
 Text 
Article 210 Branch Circuits Not Over 1000 Volts ac, 1500 
Volts dc, Nominal
210.8 Ground-Fault Circuit-Interrupter Protection
for Personnel. 
(D) Specic Appliances. GFCI protection shall be provided 
for the branch circuit or outlet supplying the following 
appliances rated 150 volts or less to ground and 60 amperes 
or less, single- or 3-phase: 
(1) Automotive vacuum machines 
(2) Drinking water coolers and bottle ll stations 
(3) High-pressure spray washing machines 
(4) Tire ination machines 
(5) Vending machines 
(6) Sump pumps 
(7) Dishwashers 
(8) Electric ranges 
(9) Wall-mounted ovens
(10) Counter-mounted cooking units
(11) Clothes dryers
(12) Microwave ovens
Expert Analysis 
A revision has been made to clarify that GFCI protection 
continued on page 20