Install Instructions

Modes
When to use
this setting
Amount of
Ambient Light
Present
Turns light
ON when...
Light turns OFF
when...
Occupancy
(DOS02 only)
When
automatic ON/
OFF lighting
control is
desired.
1.
Low - Light
will turn ON
automatically
if room is
darkest.
2.
Medium- Light
will turn ON
automatically
if room has
more light.
3.
High - Light
will turn ON
automatically
if room has
the most light
4.
Disabled -
Light will turn
ON always.
User walks into
the view of the
sensor when the
light is OFF and
it is darker than
the ambient light
level set.
OR
TOP or BOTTOM
of button is
pushed.
No motion is
detected for the
duration of the
programmed time
period.
OR
TOP or BOTTOM
of button is
pushed.
Vacancy
When Manual
ON, Automatic
OFF lighting
control is
desired.
N/A
TOP or BOTTOM
of button is
pushed.
OR
User moves
around within 30
secs of the light
turning OFF.
TOP or BOTTOM
of button is
pushed.
OR
No motion is
detected for the
duration of the
programmed time
period.
For Technical Assistance Call: 1-800-824-3005 (USA Only)
or 1-800-405-5320 (Canada Only) www.leviton.com
PK-A3345-10-00-2A
© 2021 Leviton Mfg. Co., Inc.
What to do if...
Issue
Make this adjustment
Lights do not operate with push pad and RED indicator does not
blink when motion is present.
Verify wiring connections to sensor.
Lights do not switch ON when motion is detected (DOS02).
Motion is beyond sensing range - move closer to switch.
Adjust the light level lower (Option 3, 2, 1 or disable).
The RED light will blink to indicate motion. If it is blinking and the load is not turning ON, it could be due
to ambient light OR check to make sure that the Occ-Vac switch is in OCC position.
Lights always stay ON.
Check time delay settings and compare to how long the lights stay ON.
Make sure no motion occurs in coverage area for time selected by covering the lens.
Check that switch is not installed near a heat source (like stove, lights, heat vents) or detecting motion
from an adjacent area (like hallway traffic) and if it is, relocate it.
Lights do not turn ON (DVS02).
Make sure that control is installed correctly.
Make sure the power is ON.
Check to make sure the light bulb is functional.
FCC STATEMENT: This device complies with Part 15 of the FCC Rules. Operation is subject to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation of the device. This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is
encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving Antenna. • Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/tv technician for help.
FCC CAUTION: Any changes or modifications not expressly approved by Leviton Manufacturing Co., Inc., could void the user's authority to operate the equipment.
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada Ltd to the attention of the Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R
1E9 or by telephone at 1-800-405-5320.
LIMITED 5 YEAR WARRANTY For Leviton’s limited product warranty, go to www.leviton.com. For a printed copy of the warranty,call 1-800-824-3005.
Patents covering this product, if any, can be found on www.leviton.com/patents.
Leviton, the Leviton logo and Decora are the registered trademarks of Leviton Mfg. Co., Inc.
Sensing Area Coverage
1. Horizontal field of view:
2. Vertical field of view:
Changing your device color
Remove Replace
VAC
VAC
3. Using advanced modes.
Programming (cont'd)
15 FT
10 FT
0
10 FT
15 FT
20 FT 30 FT
Major motion coverage 900ft
2
Minor motion coverage 400ft
2
40-48 IN
20 FT 30 FT
Mode name To enable this mode... The device will...
Test Mode
Press and hold
TOP of
button for 5 seconds.
To exit, press TOP or
BOTTOM of button or
it will automatically exit
after 2 minutes.
Turn on the load for 5 seconds
every time motion is detected. RED
light will blink 1x/2 sec when in
Test Mode. Locator LED function
is disabled while motion detection
function is active.
Temporary
Bypass Mode
(Available for
occupancy
sensors only)
Press and hold
BOTTOM of button for 5
seconds. To exit, press
TOP or BOTTOM of
button.
Ignore motion keeping the light/load
off. GREEN light will double flash
every 2 seconds.
Programming
Mode
(See Programming
directions above)
Hold TOP and
BOTTOM of button for 5
seconds.
GREEN light will be solid ON
for 5 seconds. NOTE: If nothing
happens, device is already in
programming mode.
OCC
VAC
Occupancy/Vacancy Switch (DOS02 only)
Remove color kit and wallplate to access.
2. When to use Occupancy or Vacancy.
OCC
VAC
NOTE:
When pressing the button to turn the light OFF manually, the sensor will
ignore motion for 30 seconds to allow user to exit the room (without re-
triggering the light).
WEB VERSION