Instructions / Assembly

Single Pole (One location) or 3-Way (Multi-location)
Universal Incandescent/Magnetic Low Voltage/Fluorescent or LED Dimmer
Cat. No. DDMX1-BL, 1000VA, 1000W, 450W LED/CFL (Lighted)
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
IMPORTANT: For 3-Way applications, note that one of the screw terminals
from the old switch being removed will usually be a different color (Black)
or labeled Common. Tag that wire with electrical tape and identify as the
common (Line or Load) in both the dimmer wall box and remote wall box.
For non-standard wiring applications, refer
to Wire Nut and Connector Size Chart
1 - #12 w/ 1 to 3 #14, #16 or #18
2 - #12 w/ 1 or 2 #16 or #18
1 - #14 w/ 1 to 4 #16 or #18
2 - #14 w/ 1 to 3 #16 or #18
WIRE CONNECTOR / # OF COND.
COMBINATION CHART
DI-000-DDMX1-02A
Pull off pre-cut insulation from dimmer leads.
Make sure that the ends of the wires from the wall box are straight
(cut if necessary).
Remove insulation from each wire in the wall box as shown.
For Single-Pole Application, go to Step 4a.
For 3-Way Matching Remote (w/LEDs) Application, go to Step
4b.
Step 4b
TOOLS NEEDED TO INSTALL YOUR DIMMER
Slotted/Phillips Screwdriver Electrical Tape Pliers
Pencil Cutters Ruler
MULTI-DEVICE APPLICATION
In multi-dimmer installations, the reduction of the dimmer’s capacity may
be required. Refer to the chart for maximum load per dimmer.
NOTE: No derating is required for LED or CFL bulb applications.
If installing Dimmer in a single device application, proceed with the
INSTALLING YOUR DIMMER section. If installing Dimmer in a
multi-device application, proceed as follows:
INSTALLING DIMMER BY ITSELF
OR WITH OTHER DEVICES
Changing the color of your Dimmer:
Your device may include color options. To change color of the face
proceed as follows:
1
2
Insert top tabs and
press in bottom tabs
to attach
Push in sides at bottom
tabs and pull outward to
release
INSTALLING YOUR DIMMER
NOTE: Use check boxes when Steps are completed.
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN
OFF POWER at circuit breaker or fuse and test that power
is off before wiring!
Step 1
Step 2
Identifying your wiring application (most common):
NOTE: If the wiring in your wall box does not resemble any
of these configurations, consult an electrician.
2
4
3
1
Single Pole
1.
Line (Hot)
2. Neutral
3. Ground
4. Load
3-Way
1.
Line or Load
(see important
instruction)
2. Neutral
3. Ground
4. First Traveler – note color
5. Second Traveler – note color
2
4
1
5
3
Cut
(if necessary)
5/8"
(1.6 cm)
Strip Gage
(measure bare
wire here)
Preparing and connecting wires:
Pull off pre-cut insulation from dimmer leads. Make sure that
the ends of the wires from the wall box are straight (cut if
necessary). Remove insulation from each wire in the wall box
as shown:
Step 3
Dimmer
Insulating
Label
Black
Load
Hot (Black)Black
Line
120 VAC,
60Hz
Neutral (White)
Red
Yellow/Red
White
White
Green
Ground
White
Red
Green
Black
1
4
2
3
Insulating label:
This wire is used in 3-way installations only.
For single pole installations, do not remove insulating label.
Yellow/Red
Single Pole Wiring Application:
Step 4a
MAXIMUM BULB WATTAGE
Low-voltage dimmers are rated in Volt-Amps (VA). The maximum bulb wattage
is determined by the efficiency of the transformer in the low-voltage lighting
system. Transformer efficiencies will vary from different manufacturers;
consider 80% efficient as average. Use the chart to determine maximum bulb
wattage for typical transformer efficiency ratings.
MAXIMUM BULB WATTAGE
Mark 10
®
Powerline dimmers are rated in Volt-Amps (VA). The maximum bulb
wattage is determined by the efficiency of the Mark 10
®
Powerline ballast. The
following table shows the maximum number of ballasts that can be connected
to a single dimmer for different Mark 10
®
Powerline ballasts. Also note that the
table shows maximum ballasts for multi-gang installations.
Lutron Tu-Wire
®
:
To determine total ballast load, add the line current found on the ballast label
for all ballasts in the circuit. This will indicate the total load for the control.
Remove all
inner side
sections
Do not
remove
outer side
sections
Bend back and
forth to remove
side section
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
More than 2 Devices
700W
700VA
Two Devices
800W
800VA
Single
1000W
1000VA
Load
Incand
Mag LV
MAXIMUM BULB WATTAGE AT 75% EFFICIENCY
More than 2 Gang
560W
Rating
1000VA
Single
800W
Two Gang
640W
INTRODUCTION
The next generation of lighting control technology is here with the new
Decora
®
Digital Dimmer with Bluetooth
®
Technology. This innovative
device works using the Leviton Decora
®
Digital Dimmer & Timer app
that can be easily downloaded to smartphones or tablets and paired
to the Leviton Dimmer using Bluetooth
®
technology. Decora
®
Digital
Devices give users point-to-point local control to automate lighting,
bridging the gap between standard dimmers and whole-house
automation systems.
The Decora
®
Digital Dimmer is a powerful device – combining the best
of Leviton dimmer and timer functions with today’s mobile technology
for impressive results. The simple touch of a finger following the
intuitive on-screen guide makes it more convenient than ever to
manage lighting for home activities or to ensure a "lived-in" look while
away. Plus, the Decora
®
Digital Dimmer is Universal and compatible
with LED, CFL, Incandescent, Halogen or Mark 10
®
Powerline loads.
Use of the app allows greater flexibility for accurate timer functionality
and makes pushing buttons for timed events a tedious chore of the
past.
The Leviton Decora
®
Digital Dimmer & Timer app can be easily
downloaded to mobile devices and is compatible with Android and iOS
smartphones or tablets. The app is easy to use with simple, intuitive
on-screen menu options to independently control dimmers and
switches throughout the home.
Decora
®
Digital Devices are ideal for living rooms, bedrooms, kitchens,
dining rooms, home offices, outdoor lighting or anywhere full control of
lighting is desired.
Soft fade ON/OFF
ON/OFF LED and Brightness level LED
Three way communication
Ease of installation – No new wiring
FEATURES
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
WARNING: CONNECT A MAGNETIC LOW-VOLTAGE DIMMER ONLY
TO THE PRIMARY (HIGH-VOLTAGE) SIDE OF A MAGNETIC
LOW-VOLTAGE TRANSFORMER.
NOTE: The DDMX1 dimmer requires a neutral wire connection.
Green or bare copper wire in wall box to Green dimmer lead.
Line Hot wall box wire to Black dimmer lead.
Load wall box wire to Red dimmer lead.
Line Neutral wall box wire to White dimmer lead.
Yellow/Red dimmer lead should have Red insulation label affixed.
NOTE: If insulating label is not affixed to Yellow/Red dimmer lead, use
electrical tape to cover.
Proceed to Step 5.
Cat. No. DDMX1, 120V, For use with Advance Transformer
120V Mark 10
®
Powerline Electronic Ballasts
Max. # Ballasts/Dimmer for
Multi-gang
Advance
Mark 10
®
Powerline
Part No.
Lamp
Single
Gang
Two
Ganged
More than
2 Gang
REZ-2Q18-M2-LD
REZ-1T32
REZ-2Q26
REZ-1T32
REZ-1T42
REZ-1Q18-M2-BS
REZ-1Q18-M2-LD
REZ-2Q18-M2-BS
REZ-1T32
REZ-1T42-M2-BS
REZ-1T42-M2-LD
REZ-2Q26
REZ-2Q26-M2-BS
REZ-2Q26-M2-LD
REZ-1Q18-M2-BS
REZ-1Q18-M2-LD
REZ-2Q18-M2-BS
REZ-2Q18-M2-LD
REZ-1T42-M2-BS
REZ-1T42-M2-LD
REZ-2Q26-M2-BS
REZ-2Q26-M2-LD
REZ-1T42-M2-BS
REZ-1T42-M2-LD
REZ-2T42-M3-BS CFTR32W/GX24Q 13 10 8
CFTR32W/GX24Q 26 20 16
CFTR32W/GX24Q 26 20 16
CFTR26W/GX24Q 17 13 11
CFTR26W/GX24Q 17 13 11
CFTR26W/GX24Q 32 25 20
CFTR26W/GX24Q 32 25 20
CFTR18W/GX24Q 23 18 15
CFTR18W/GX24Q 23 18 15
CFTR18W/GX24Q 46 37 30
CFTR18W/GX24Q 46 37 30
CFQ26W/G24Q 17 13 11
CFQ26W/G24Q 17 13 11
CFQ26W/G24Q 17 13 11
CFQ26W/G24Q 32 25 20
CFQ26W/G24Q 32 25 20
CFQ26W/G24Q 32 25 20
CFQ18W/G24Q 23 18 15
CFQ18W/G24Q 46 37 30
CFQ18W/G24Q 46 37 30
CFM42W/GX24Q 20 16 13
CFM32W/GX24Q 26 20 16
CFM26W/GX24Q 17 13 11
CFM26W/GX24Q 32 25 20
151823CFM18W/GX24Q
WARNINGS AND CAUTIONS:
TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!
TO AVOID FIRE, PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to control a receptacle, a motor- or a transformer-operated appliance.
To be installed and/or used in accordance with electrical codes and regulations.
If you are unsure about any part of these instructions, consult an electrician.
Use ONLY with the appropriate Advance Transformer 120V Mark 10
®
Powerline or Lutron Tu-Wire
®
electronic ballasts for controlling the specific fluorescent lamps in Fluorescent Mode.
Use with magnetic low voltage transformers, incandescent, or 120V halogen fixtures only. Use a Leviton electronic low voltage dimmer to control electronic (solid state) low voltage transformers.
When retrofitting Mark 10
®
Powerline dimming ballasts into fixtures that originally had Instant Start ballasts, the sockets MUST be replaced with Rapid Start sockets to allow proper dimmer
operation and prevent damage to the dimmer ballast. Refer to the instructions provided with the ballast.
The Decora
®
DDMX1 dimmer is not compatible with standard 3-way or 4-way switches. It must be used with the
Decora
®
Digital DD00R-DL remote for multi-location dimming
.
WARNINGS AND CAUTIONS:
Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.
Dimmer may feel warm to the touch during normal operation.
When magnetic low voltage circuits are operated at a dim level, with all lamps inoperative, excess current may flow through the transformer. To avoid possible transformer failure due to
overcurrent, use a transformer that incorporates thermal protection or a fuse at the primary windings.
Recommended minimum wall box depth is 2-3/4".
Use this device WITH COPPER OR COPPER CLAD WIRE ONLY.
Use with compatible dimmable LED, CFL bulbs, incandescent or 120V halogen fixtures only. For a list of compatible LED and CFL bulbs refer to www.leviton.com.
When multiple bulbs are used with one dimmer DO NOT mix bulb types. All bulbs shall be either LED; CFL or incandescent. Using the same make/model of each bulb will enhance
dimmer performance.
WIRING MATCHING REMOTE (wall box with line hot
connection):
Connect wires per WIRING DIAGRAM as follows:
NOTE: The matching remote must be installed in a wall box with a
Line Hot connection and a Neutral connection. A Neutral wire to the
matching remote needs to be added as shown.
NOTE: Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft (90 m).
Green or bare copper wire in wall box to Green terminal screw.
Line Hot (common) wall box wire identified (tagged) when removing
old switch and First Traveler to Remote terminal marked "BK".
Second Traveler wall box wire from dimmer to remote terminal screw
marked "YL/RD" (note wire color). This traveler from the remote
must go to Yellow/Red dimmer lead.
Line Neutral wall box to remote terminal screw marked "WH".
WIRING DIMMER (wall box with load connection):
Connect wires per WIRING DIAGRAM as follows:
NOTE: The DDMX1 dimmer must be installed in a wall box that has a
Load connection and a Neutral connection.
Green or bare copper wire in wall box to Green dimmer lead.
Load wall box wire identified (tagged) when removing old switch to
Red dimmer lead.
First Traveler Line Hot to Black dimmer lead.
Remove Red insulating label from Yellow/Red dimmer lead.
Second Traveler wall box wire (note color as above) to
Yellow/Red dimmer lead. This traveler from the dimmer must go to
the terminal screw on the remote marked "YL/RD".
Line neutral wall box wire to White dimmer lead.
Proceed to Step 5.
Hot (Black)
Neutral (White)
Dimmer
Matching Remote (w/LEDs)
YL/RD
Red
Yellow/
Red
WH BK
Black
Black
White
Line
120V
AC, 60Hz
Green
Ground
Green
Ground
White
Load
3-Way Wiring with DD00R Matching Remote
(w/LEDs) Application:
Matching Remote Dimmer
Additional Neutral Wire
White
Red
Green
Black
1
2
3
Yellow/Red
4
5
1
2
3
4
5

Summary of content (2 pages)