FAQ
72
Leviton Extra Duty While-In-Use Covers
Material taken from the National Electric Code
®
 is reprinted with permission 
from NFPA 70
®
, 2023 edition. National Electrical Code
®
, Copyright 2022, 
National Fire Protection Association, Quincy, MA. All rights reserved.
NEC
®
 Text 
Exception: 15- and 20-ampere, 125- through 250-volt receptacles installed 
in a wet location and subject to routine high-pressure spray washing shall be 
permitted to have an enclosure that is weatherproof when the attachment plug 
is removed.
All 15- and 20-ampere, 125- and 250-volt nonlocking-type 
receptacles shall be listed and so identied as the 
weather-resistant type.
Informational Note No. 2: See ANSI/NEMA WD 6–2016, 
Wiring Devices — Dimensional Specications, for receptacle 
congurations. The conguration of weather-resistant receptacles 
covered by this requirement are identied as 5-15, 5-20, 6-15, 
and 6-20.
Expert Analysis 
A revision has been made pertaining to receptacles in 
damp or wet locations to require hinged covers of outlet 
box hoods to be installed to allow the cover to open to 
either 90 degrees, or fully open depending on 
cover type. The significance is that the covers swing 
can't be blocked by any obstruction.
Leviton Solution 
Leviton Extra Duty While-In-Use Covers
Built to withstand the elements and tough enough 
to comply with 406.9(B)(1) for “Extra-Duty”
• Accommodates Decora
®
 GFCI devices. Adapter plates 
  are included for duplex and single receptacles
• Heavy-duty gasket protects from moisture and adds 
  to ease of installation
• Includes two inserts to cover cord openings to prevent 
  insects and debris from entering the cover
• Safety lock feature 
continued from page 71