Installation Guide
NOTE FROM THE MANUFACTURER
This document provides instructions for this Level 2 EVSE Charging Station and should not be
used for any other product. Before installation or use of this product, review instructions carefully
and consult with a licensed contractor, electrician, or trained installation expert to ensure
compliance with local building codes and safety standards.
READY
CHARGE
FAULT
OVERVIEW
Status Indicator
Release
Button
J1772
TM
Charge
Connector
Charge
Connector
Cord
2
NEMA 6-30
AC Power Plug
STATUS INDICATOR
Power
(Green LED)
Charging
(Yellow LED)
Fault
(Red LED)
Status
OFF OFF OFF
When the EVSE Charging Station is not
energized, all indicator LEDs are OFF.
ON OFF OFF
Power indicator LED illuminates green when
plugged into AC power outlet. Charging connector
is not yet coupled with electric vehicle charge port.
ON ON OFF
Charging connector is correctly coupled with
electric vehicle charge port. Charging is not yet in
progress.
ON Flashing OFF
Electric vehicle charging in progress.
ON OFF Flashing
EVSE Charging Station is recovering from a minor
fault. Wait until Fault indicator LED turns OFF to
resume charging.
ON OFF ON
EVSE Charging Station malfunction.
Stop using immediately. Unplug AC power plug
from outlet.