Quick Start Guide
IMPORTANT: For 3-Way applications, note that one of the screw terminals
from the old switch being removed will usually be a different color (Black)
or labeled Common. Tag that wire with electrical tape and identify as the
Common (Line or Load) in both the dimmer wall box and remote wall box.
For non-standard wiring applications, refer
to Wire Connector and Conductor Size Chart
1 - #12 w/ 1 to 3 #14, #16 or #18
2 - #12 w/ 1 or 2 #16 or #18
1 - #14 w/ 1 to 4 #16 or #18
2 - #14 w/ 1 to 3 #16 or #18
WIRE CONNECTOR / # OF COND.
COMBINATION CHART
• Pull off pre-cut insulation from dimmer leads.
• Make sure that the ends of the wires from the wall box are straight
(cut if necessary).
• Remove insulation from each wire in the wall box as shown.
• For Single-Pole Application, go to Step 4a.
• For 3-Way Matching Remote (w/LEDs) Application, go to Step 4b.
Step 4b
MULTI-DIMMER APPLICATION
In multi-dimmer installations, the reduction of the dimmer’s capacity may
be required. Refer to the chart for maximum load per dimmer.
NOTE: No derating is required for LED or CFL bulb applications.
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&/./&&
/./&&
/./&&
/./&&
/./&&
WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN
OFF POWER at circuit breaker or fuse and test that power
is off before wiring!
Step 1
Step 2
Identifying your wiring application (most common):
NOTE: If the wiring in your wall box does not resemble any
of these configurations, consult an electrician.
2
4
3
1
Single Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load
3-Way
1. Line or Load
(see important
instruction)
2. Neutral
3. Ground
4. First Traveler – note color
5. Second Traveler – note color
2
4
1
5
3
Cut
(if necessary)
5/8"
(1.6 cm)
Strip Gage
(measure bare
wire here)
Preparing and connecting wires:
Step 3
Dimmer
Insulating
Label
Black
Load
Hot (Black)Black
Line
120 VAC,
60Hz
Neutral (White)
Red
Yellow/Red
White
White
Green
Ground
White
Red
Green
Black
1
4
2
3
Insulating label:
This wire is used in 3-way installations only.
For sin
g
le
p
ole installations
,
do not remove insulatin
g
label.
Yellow/Red
Single Pole Wiring Application:
Step 4a
MAXIMUM BULB WATTAGE
Low-voltage dimmers are rated in Volt-Amps (VA). The maximum bulb wattage
is determined by the efficiency of the transformer in the low-voltage lighting
system. Transformer efficiencies will vary from different manufacturers;
consider 80% efficient as average. Use the chart to determine maximum bulb
wattage for typical transformer efficiency ratings.
MAXIMUM BULB WATTAGE
Mark 10
®
Powerline dimmers are rated in Volt-Amps (VA). The maximum bulb
wattage is determined by the efficiency of the Mark 10
®
Powerline ballast. The
following table shows the maximum number of ballasts that can be connected
to a single dimmer for different Mark 10
®
Powerline ballasts. Also note that the
table shows maximum ballasts for multi-gang installations.
Lutron Tu-Wire
®
:
To determine total ballast load, add the line current found on the ballast label
for all ballasts in the circuit. This will indicate the total load for the control.
Remove all
inner side
sections
Do not
remove
outer side
sections
Bend back and
forth to remove
side section
MAXIMUM LOAD PER DIMMER FOR MULTI-GANG
More than 2 Gang
700W
700VA
Two Gang
800W
800VA
Single
1000W
1000VA
Load
Incand
Mag LV
MAXIMUM BULB WATTAGE AT 75% EFFICIENCY
More than 2 Gang
560W
Rating
1000VA
Single
800W
Two Gang
640W
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
WARNING: CONNECT A MAGNETIC LOW-VOLTAGE DIMMER ONLY
TO THE PRIMARY (HIGH-VOLTAGE) SIDE OF A MAGNETIC
LOW-VOLTAGE TRANSFORMER.
NOTE: The DH1KD dimmer requires a Neutral wire connection.
• Green or bare copper wire in wall box to Green dimmer lead.
• Line Hot wall box wire to Black dimmer lead.
• Load wall box wire to Red dimmer lead.
• Line Neutral wall box wire to White dimmer lead.
• Yellow/Red dimmer lead should have Red insulation label affixed.
NOTE: If insulating label is not affixed to Yellow/Red dimmer lead, use
electrical tape to cover.
• Proceed to Step 5.
Cat. No. DH1KD, 120V, For use with Advance Transformer
120V Mark 10
®
Powerline Electronic Ballasts
Max. # Ballasts/Dimmer for
Multi-gang
Advance
Mark 10
®
Powerline
Part No.
Lamp
Single
Gang
Two
Ganged
More than
2 Gang
REZ-2Q18-M2-LD
REZ-1T32
REZ-2Q26
REZ-1T32
REZ-1T42
REZ-1Q18-M2-BS
REZ-1Q18-M2-LD
REZ-2Q18-M2-BS
REZ-1T32
REZ-1T42-M2-BS
REZ-1T42-M2-LD
REZ-2Q26
REZ-2Q26-M2-BS
REZ-2Q26-M2-LD
REZ-1Q18-M2-BS
REZ-1Q18-M2-LD
REZ-2Q18-M2-BS
REZ-2Q18-M2-LD
REZ-1T42-M2-BS
REZ-1T42-M2-LD
REZ-2Q26-M2-BS
REZ-2Q26-M2-LD
REZ-1T42-M2-BS
REZ-1T42-M2-LD
REZ-2T42-M3-BS
CFTR32W/GX24Q 13 10 8
CFTR32W/GX24Q 26 20 16
CFTR32W/GX24Q 26 20 16
CFTR26W/GX24Q 17 13 11
CFTR26W/GX24Q 17 13 11
CFTR26W/GX24Q 32 25 20
CFTR26W/GX24Q 32 25 20
CFTR18W/GX24Q 23 18 15
CFTR18W/GX24Q 23 18 15
CFTR18W/GX24Q 46 37 30
CFTR18W/GX24Q 46 37 30
CFQ26W/G24Q 17 13 11
CFQ26W/G24Q 17 13 11
CFQ26W/G24Q 17 13 11
CFQ26W/G24Q 32 25 20
CFQ26W/G24Q 32 25 20
CFQ26W/G24Q 32 25 20
CFQ18W/G24Q 23 18 15
CFQ18W/G24Q 46 37 30
CFQ18W/G24Q 46 37 30
CFM42W/GX24Q 20 16 13
CFM32W/GX24Q 26 20 16
CFM26W/GX24Q 17 13 11
CFM26W/GX24Q 32 25 20
151823CFM18W/GX24Q
WARNINGS AND CAUTIONS
• Dimmer may feel warm to the touch during normal operation.
• When magnetic low voltage circuits are operated at a dim level, with all lamps inoperative, excess current may flow through the transformer. To avoid possible transformer failure due to over
current, use a transformer that incorporates thermal protection or a fuse at the primary windings.
• Recommended minimum wall box depth is 2-3/4".
• Use this dimmer with copper or copper clad wire only.
• Use with compatible dimmable LED, CFL bulbs, incandescent or 120V halogen fixtures only. For a list of compatible LED and CFL bulbs refer to www.leviton.com.
•
DO NOT mix bulb types when multiple bulbs are used with one dimmer. All bulbs shall be either LED; CFL or incandescent. Using the same make/model of each bulb will enhance dimmer performance.
• Leviton HomeKit-enabled accessories rely on Wi-Fi
®
communication. Increasing the number of Wi-Fi
®
accessories can affect Wi-Fi
®
performance. Consult the network’s wireless access point
specifications to determine the maximum number of supported Wi-Fi
®
accessories. For installations with a large number of Leviton HomeKit Wi-Fi
®
accessories, a high performance wireless
access point capable of supporting a large number of accessories may be required.
WIRING DIMMER
(wall box with load connection):
Connect wires per WIRING DIAGRAM as follows:
NOTE: The DH1KD dimmer must be installed in a wall box that has a
Load connection and a Neutral connection.
• Green or bare copper wire in wall box to Green dimmer lead.
• Load wall box wire identified (tagged) when removing old switch to
Red dimmer lead.
• First Traveler Line Hot to Black dimmer lead.
• Remove Red insulating label from Yellow/Red dimmer lead.
• Second Traveler wall box wire (note color as above) to
Yellow/Red dimmer lead. This traveler from the dimmer must go to
the terminal screw on the remote marked "YL/RD".
• Line neutral wall box wire to White dimmer lead.
WIRING MATCHING REMOTE
(wall box with line hot connection):
Connect wires per WIRING DIAGRAM as follows:
NOTE: The matching remote must be installed in a wall box with a
Line Hot connection and a Neutral connection. A Neutral wire to the
matching remote needs to be added as shown.
NOTE: Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft (90 m).
• Green or bare copper wire in wall box to Green terminal screw.
• Line Hot (common) wall box wire identified (tagged) when removing
old switch and First Traveler to Remote terminal marked "BK".
• Second Traveler wall box wire from dimmer to remote terminal screw
marked "YL/RD" (note wire color). This traveler from the remote
must go to Yellow/Red dimmer lead.
• Line Neutral wall box to remote terminal screw marked "WH".
• Proceed to Step 5.
Hot (Black)
Neutral (White)
Dimmer
Matching Remote (w/LEDs)
YL/RD
Red
Yellow/
Red
WH BK
Black
Black
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
White
Load
3-Way Wiring with DD00R Matching Remote
(w/LEDs) Application:
Matching Remote Dimmer
Additional Neutral Wire
White
Red
Green
Black
1
2
3
Yellow/Red
4
5
1
2
3
4
5
WARNINGS AND CAUTIONS
• TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!
•
TO AVOID FIRE, PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to control a receptacle, a motor, or a transformer operated appliance.
• To be installed and/or used in accordance with electrical codes and regulations.
• If you are unsure about any part of these instructions, consult an electrician.
•
Use with magnetic low voltage transformers, incandescent, or 120V halogen fixtures only. Use a Leviton electronic low voltage dimmer to control electronic (solid state) low voltage transformers.
• Use ONLY with the appropriate Advance Transformer 120V Mark 10
®
Powerline or Lutron Tu-Wire
®
electronic ballasts for controlling the specific fluorescent lamps in Fluorescent Mode.
• When retrofitting Mark 10
®
Powerline dimming ballasts into fixtures that originally had Instant Start ballasts, the sockets MUST be replaced with Rapid Start sockets to allow proper
dimmer operation and prevent damage to the dimmer ballast. Refer to the instructions provided with the ballast.
•
The Decora
Smart
TM
DH1KD dimmer is not compatible with standard 3-way or 4-way switches. It must be used with up to 4
Decora
®
Digital DD00R-DL remotes for multi-location dimming
.
• Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.
• Save this instruction sheet. It contains important technical data along with testing and troubleshooting information which will be useful after installation is complete.
INSTALLING YOUR DIMMER
NOTE: Use check boxes when Steps are completed.
TOOLS NEEDED TO INSTALL YOUR DIMMER
Slotted/Phillips Screwdriver Electrical Tape Pliers
Pencil Cutters Ruler
If installing the dimmer in a single gang application, proceed with the
INSTALLING YOUR DIMMER section. If installing dimmer in a
multi-gang application, proceed as follows:
INSTALLING DIMMER BY ITSELF
OR MULTI-GANG
Changing the color of your Dimmer:
Your dimmer comes with two color options. To change color of the face
proceed as follows:
1
2
Insert top tabs and
press in bottom tabs
to attach
Push in sides at bottom
tabs and pull outward to
release
INTRODUCTION
FEATURES
RATINGS
Incandescent - 1000W - 120VAC, 60Hz
LED/CFL - 450W - 120VAC, 60Hz
Mark 10
®
- 1000VA - 120VAC, 60Hz
REQUIRED
DI-000-DH1KD-02A
Leviton’s Decora Smart
TM
accessories are designed to streamline home
control with other HomeKit-enabled accessories. Apple HomeKit
TM
technology provides an easy, secure way to control HomeKit-enabled
accessories using Siri voice control on your iPhone or iPad. After
installing your Decora Smart
TM
Dimmer, configure it from the Leviton
Decora Smart Home app with just a few simple steps.
WARNING: TO AVOID FIRE, PERSONAL INJURY OR DEATH DO NOT
USE the remote for the control of high power heating appliances such
as portable heaters. There can be some unexpected consequences if
not used with care. For example, an empty coffee pot can be remotely
turned on. If that should happen, your coffee pot could be damaged from
overheating. If an electric heater is turned on by remote control while
clothing is draped over it, a fire could result. This device will not control
lighting that is used with electronic low-voltage and high frequency power
supply transformers, nor high pressure discharge lamps (HID lighting).
This includes mercury-vapor, sodium vapor and metal halide lamps.
Decora Smart
TM
accessories are ideal for living rooms, bedrooms,
kitchens, dining rooms, home offices, outdoor lighting or anywhere full
control of lighting is desired.
• The Leviton Decora Smart
TM
Dimmer is HomeKit-enabled using
Wi-Fi
®
technology for residential applications
• Compatible with Leviton Decora Smart Home app as well as other
HomeKit-enabled apps
• Soft fade ON/OFF
• ON/OFF LED and Brightness level LED
•
O
ver The Air (OTA) firmware updates via Leviton Decora Smart Home app
• Single pole or three way compatible
• Ease of installation - No new wiring
• Wi-Fi
®
Network
• Free Leviton Decora Smart Home app
• Controlling this HomeKit-enabled accessory away from home
requires an Apple TV (3rd generation or later) with Apple TV
software 7.0 or later and an iPhone or iPad with iOS 8.1 or later
WEB VERSION