8.0 Device and Alarm Testing
The Level Sense Pro and sensors should be tested monthly to ensure
proper operation.
8.1 Humidity and Temperature Testing
Testing for temperature and humidity sensors is done by comparing
current levels in Portal with a calibrated reference. Readings of +/-3%
are expected.
8.2 Float Switch Testing
8.3 Leak Sensor Testing
Test the leak sensor by dipping both metal tabs of the sensor into
a cup of water and waiting 60 seconds for an alarm. Do not submerge
the plastic housing of the sensor. Dry the metal tabs and replace the
sensor after testing.
8.4 Power Loss Detection Testing
Test power loss detection by removing the power adapter from the
wall and waiting for alarm. Reconnect the power adapter after testing.
8.5 Battery Condition Testing
Remove the power adapter from the wall and allow the device to run
before three hours replace the battery. Dispose battery according to
local rules and regulations.
9.0 Maintenance
Level Sense Pro and sensors require the following monthly
Inspect the leak sensor contacts for corrosion and clean or replace
Check the level sensor has not come loose from the
PVC pipe. Check for fraying wire, loose connections
or other general wear and replace if necessary.
15
7HVWWKHȵRDWVZLWFKE\KROGLQJWKHȵRDWXSVLPXODWLQJKLJKZDWHU
DQGZDLWLQJVHFRQGVIRUDQDODUP5HOHDVHWKHȵRDWDIWHUWHVWLQJ