Datasheet

Diagnostics and troubleshooting
Leuze electronic RSL 410 81
P0424 Safety configuration is not compatible:
unknown parameter for manipulation moni-
toring.
Swap out the safety sensor or change the
configuration. The type of safety sensor
must be the same as the type stored in the
connection unit or in the
Sensor Studio
soft-
ware.
P0425 Safety configuration is not compatible:
unknown configuration of the output signals.
Swap out the safety sensor or change the
configuration. The type of safety sensor
must be the same as the type stored in the
connection unit or in the
Sensor Studio
soft-
ware.
P0426 Safety configuration is not compatible:
unknown resolution.
Swap out the safety sensor or change the
configuration. The type of safety sensor
must be the same as the type stored in the
connection unit or in the
Sensor Studio
soft-
ware.
P0427 Safety configuration is not compatible:
unknown parameter.
Swap out the safety sensor or change the
configuration. The type of safety sensor
must be the same as the type stored in the
connection unit or in the
Sensor Studio
soft-
ware.
P0428 Safety configuration is not compatible:
unknown reflector mode.
Swap out the safety sensor or change the
configuration. The type of safety sensor
must be the same as the type stored in the
connection unit or in the
Sensor Studio
soft-
ware.
P0429 Safety configuration is not compatible:
unknown start/restart mode.
Swap out the safety sensor or change the
configuration. The type of safety sensor
must be the same as the type stored in the
connection unit or in the
Sensor Studio
soft-
ware.
P0430 Safety configuration is not compatible:
unknown start mode.
Swap out the safety sensor or change the
configuration. The type of safety sensor
must be the same as the type stored in the
connection unit or in the
Sensor Studio
soft-
ware.
P0431 Safety configuration is not compatible:
unknown restart mode.
Swap out the safety sensor or change the
configuration. The type of safety sensor
must be the same as the type stored in the
connection unit or in the
Sensor Studio
soft-
ware.
P0432 Safety configuration is not compatible:
unknown OSSD stop mode.
Swap out the safety sensor or change the
configuration. The type of safety sensor
must be the same as the type stored in the
connection unit or in the
Sensor Studio
soft-
ware.
U0573 EDM fault at system start. Check the wiring of the downstream relays
and that they are functioning correctly.
U0574 Switching fault, EDM at OSSD A: external
relay does not switch off.
Check the wiring of the downstream relays
and that they are functioning correctly.
Diagnos-
tic ID
Diagnostics message Measure