Datasheet
Electrical connection
Leuze electronic RSL 410 59
Table 8.1: Interfaces
The control cable is permanently attached to the connection unit. A protection cap on the connection unit
protects the communication interface when no PC is connected.
8.2.1 Pin assignment for control M12
The safety sensor is equipped with a connection cable with a 8-pin M12 connector.
Figure 8.1: Pin assignment of safety sensor
Table 8.2: Pin assignment
8.2.2 Pin assignment of M12 Ethernet interface (communication) ( D-coded)
The safety sensor is equipped with a 4-pin M12 connector.
Interface Type Function
Control M12 connec-
tor, 8-pin
• Power supply
• Switching lines and signal lines
Communica-
tion
M12 – RJ 45 Configuration interface and data interface:
• Parameter configuration
• Protective field definition and warning field definition
• Data transmission and measurement value transmission
• Diagnosis
4
3
5
6
1
8
7
2
FE
Pin Core color Signal Description
1 White RES1 Start/restart input, protective function A
Acknowledgement
2 Brown UB Supply voltage
3 Green EA1 Contactor monitoring OSSD A
State signaling, configurable
4 Yellow A1 State signaling
5 Gray OSSDA1 Safety-related switching output, protective
function A
6 Pink OSSDA2 Safety-related switching output, protective
function A
7 Blue GND / Ground Supply voltage ground
8 Red MELD Output signal
State signaling, configurable
M12 thread FE Functional earth, connection cable shield.
The shield of the connection cable is on the
thread of the M12 plug. The thread is part of
the metallic housing.