Overview of the function modes
Table 5.2: Function modes
5.2.1 One protective function
A fixed field pair for safety-related switching outputs OSSD-A.
5.2.2 One protective function - four field mode
The safety sensor monitors one protection field and three warning fields.
Monitoring is performed together for the field pairs of protective function A and protective function B. If, for
example, the control system is monitoring field pair A1.1 for protective function A, field pair B1.1 for protec-
tive function B is also monitored.
1 Protective function A: protective field
2 Protective function B: protective field
3 Protective function A: warning field
4 Protective function B: warning field
Figure 5.1: Four field mode
If the protective field of protective function A is violated, safety-related switching outputs OSSD-A switch.
If the protective field of protective function B is violated, the indication signal B-CLEAR is generated – the
safety-related switching outputs do not switch.
The signals are assigned to the switching outputs via the configuration and diagnostics software
(CONFIGURATION > Outputs; see chapter 9 "Configuring the safety sensor").
Table 5.3: Example: Assignment of signals to switching outputs
Function mode Field pairs (FP)
Protective field (PF)
Warning field (WF)
Field pair activation
One protective function 1 FP / 1 PF + 1 WF Fixed selection of a field pair
One protective function - four field
mode
1 FP / 1 PF + 3 WF Fixed selection of a field pair
A1.1P
B1.1P
A1.1W
B1.1W
1
2
3
4