Datasheet
Device description
Leuze electronic RSL 410 16
3.3.2 Alphanumerical display
In normal operation, the 24-digit alphanumerical display of the safety sensor shows the monitored protec-
tive and warning field pairs. It also provides assistance during detailed fault diagnosis (see chapter 12).
Table 3.3: Alphanumerical displays
Display Description Example
Upon startup without configuration/upon initial commissioning
Sensor type Sensor type 420M
Sensor serial number Serial number of the sensor SN: 21513123456
Sensor name / Network
name
Name of the sensor / network A123456789
Configuration necessary Configuration required CONFIG REQUESTED
Repeated until end of booting phase / start phase, then
Spirit level permanent Horizontal alignment in degrees: H
Vertical alignment in degrees: V
H -3° V +9°
Upon startup with configuration
Sensor type Sensor type 410XL
Sensor serial number Serial number of the sensor SN: 21513123456
Sensor name / Network
name
Name of the sensor / network A123456789
IP: DHCP/FIX DHCP or permanent IP address IP: DHCP or
10.25.45.2
Bluetooth on/off Bluetooth detection ON/OFF Bluetooth ON
Date of configuration Date of configuration 11/13/2014 08:15
Signature Signature of configuration DG45L8ZU
Spirit level Horizontal alignment in degrees: H
Vertical alignment in degrees: V
H-3° V+9°
Repeated until end of booting phase / start phase, then
Display following configuration of normal operation
e.g. display of active field pair A1.1
Transfer of the configuration data
AWAITING CONFIG Until downloading of configuration data is confirmed
DOWNLOAD CONFIG During transfer of configuration data
Spirit level
H +/- ..° V +/- .. ° Horizontal alignment in degrees: H
Vertical alignment in degrees: V
H -3° V +9°
Sensor detection
PING received Display for identification by device name PING received
Device
name
Message