Datasheet
Device description
Leuze electronic RSL 410 15
• Connector bushing and EMC for the Ethernet TCP/IP communication and configuration interface to
the PC/laptop
• Memory for the configuration files and automatic parameter transfer in the event of device swap-out
• Quick-release connection to the scanner unit (see Quick Start Guide) for easy device swap-out
3.3 Display elements
The display elements of the safety sensors simplify start-up and fault analysis.
3.3.1 LED indicators
Located on the connection unit are three LEDs for displaying the operating state.
• Protective function A: LEDs 1, 2, 3
1 LED 1, red/green
2LED 2, yellow
3 LED 3, blue
4 No function
5 No function
6 No function
Figure 3.3: LED indicators
Table 3.2: Meaning of the LEDs
1
2 3 4 5 6
LED Color State Description
1 Red/green OFF Device switched off
Red OSSD off
Red, flashing Error
Green OSSD on
2 Yellow OFF RES deactivated
RES activated and enabled
Blinking Protective field occupied
ON RES activated and blocked but ready to be
unlocked
Protective field free and linked sensor enabled (if
applicable)
3 Blue OFF No internal function call active (e.g. warning field
free)
ON Internal function call (e.g. warning field occupied)