Datasheet

Device description
Leuze electronic RSL 410 14
Only when the protective field is free again does the safety sensor reset the safety-related switching func-
tion, either automatically or following acknowledgment, depending on the operating mode.
The safety sensor can even detect people when they are wearing very dark clothes, which have a very
weak diffuse reflectance.
3.1.2 Parameters for protective function
The following parameters for switching off the safety-related switching outputs of the safety sensor are
taken into consideration for the protective function:
Configurable protective fields
Reference contour of protective fields
Configurable field pair changeover
Selectable resolution for hand, leg or body detection
Safety sensor response time
Selectable start-up behavior
The following non-safety-oriented functions and signals also belong to the protective function:
Configurable warning fields
Configurable indication signals
Additional functions of the protective function
Warning field evaluation
Selectable dynamic contactor monitoring (EDM)
3.2 Connection unit
The safety sensor is mounted, connected and aligned using the connection unit.
1 M12 socket, A-coded, connection to the control
2 M12 socket, D-coded, Ethernet communication connection
M5 Connection for functional earth with M5 x 10 self-cutting/self-tapping (gas tightness) and ground
strap
Figure 3.2: Device overview, connection unit
Functions of connection unit:
Attachment point for mounting, either directly or using an optional mounting system
When devices are swapped out, the connection unit remains mounted and aligned.
EMC wiring for signal inputs/outputs and supply using M12 plug
M5 2x
2
1
Safety sensor Connection unit Connection
RSL 410 CU408-M12 M12 plug, 8-pin