Datasheet

Technical data
Leuze electronic RSL 410 103
8-11
uint32
31-0 SCAN Consecutive numbering of
scans
Resetting to 0 by switching off
--- --- Value
Protective function A
12 7 A-ACTIVE Protective function A is active /
configured
Off Active 0
6 A-WF-VIO Status of active warning field
Protective function A
Violation Free 0
5 A-PF-VIO Status of active protective field
Protective function A
Violation Free 0
4 A-RES Start/restart interlock active
Start Request A
Off Active 0
3 A-CLEAR Internal signal OSSD A Off On 0
2 reserved --- --- --- ---
1 reserved --- --- --- ---
0 reserved --- --- --- ---
Field pair selection A
13 7-4 A-BANK-SEL Selected bank A
Numbers 1 … 10
--- --- 0
3-0 A-PAIR-SEL 1 First selected field pair A
Numbers 1 … 10
--- --- 0
14 7-4 A-PAIR-SEL 2 Second selected field pair A
Numbers 1 … 10
--- --- 0
3-0 A-PAIR-SEL 3 Third selected field pair A
Numbers 1 … 10
--- --- 0
Output signals A
Byte Bit Signal Description Value “0” Value “T” Default