Datasheet

RKR 3B - 09 2014/05
Specifications
Optical data RKR 3B/…D.01… RKR 3B/66.11
Typ. op. range limit (TK(S) 100x100)
1)
1) Typ. operating range limit: max. attainable range without performance reserve
0.02 5m 0.02 7m
Operating range
2)
2) Operating range: recommended range with performance reserve
see tables
Light source
3)
3) Average life expectancy 100,000h at an ambient temperature of 25°C
LED (modulated light)
Wavelength 620nm (visible red light, not polarized)
Timing
Switching frequency 1,500Hz 1,000Hz
Response time 0.33ms 0.5ms
Delay before start-up 300ms
Electrical data
Operating voltage U
B
4)
4) For UL applications: for use in class 2 circuits according to NEC only
10 30VDC (incl. residual ripple)
Residual ripple 15% of U
B
Open-circuit current 14mA
Switching output …/44D 2 PNP switching outputs
OUT 1 (black): dark switching, n.o.
OUT 2(white): light switching, n.c.
…/22D 2 NPN switching outputs
OUT 1 (black): dark switching, n.o.
OUT 2(white): light switching, n.c.
…/66
5)
5) The push-pull switching outputs must not be connected in parallel
2 push-pull switching outputs
OUT 2 (ws/WH): PNP dark switching, NPN light switching
OUT 1 (sw/BK): PNP light switching, NPN dark switching
Function characteristics light/dark switching
6)
6) Dark switching = n.o. / light switching = n.c.
Signal voltage high/low (U
B
-2V)/ 2V
Output current max. 100mA
Operating range fixed setting
Indicators
Green LED ready
Yellow LED light path free
Mechanical data
Housing plastic (PC-ABS); 1 attachment sleeve, nickel-plated steel
Optics cover plastic (PMMA)
Weight with 2m cable: 50g
Connection type 2m cable (cross section 4x0.20mm²)
Environmental data
Ambient temp. (operation/storage) -3C +5C/-3C +7C
Protective circuit
7)
7) 2=polarity reversal protection, 3=short-circuit protection for all transistor outputs
2, 3
VDE safety class III
Protection class IP 67
Light source free group (in accordance with EN 62471)
Standards applied IEC 60947-5-2
Certifications UL 508, C22.2 No.14-13
4)
8)
8) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.5A min,
in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)
Operate in accordance with intended use!
This product is not a safety sensor and is not intended as personnel protection.
The product may only be put into operation by competent persons.
Only use the product in accordance with the intended use.
Tables
RKR 3B/…D.01…
RKR 3B/66.11
TK = adhesive
TKS = screw type
Reflectors Operating range
1 TK(S) 100x100 0.02 4.0m
2 Tape 4 50x50 0.02 1.2m
1 0,02 4 5
2 0,02 1,2 1,6
Reflectors Operating range
1 TK(S) 100x100 0.02 6.5m
2 Tape 4 50x50 0.02 2.5m
1 0,02 6,5 7
2 0,02 2,5 3
Operating range [m]
Typ. operating range limit [m]
Diagrams
Only RKR 3B/…D.01…:
-150
-100
-50
0
50
100
150
012345
6
y1
y2
Distance x [m]
Misalignment y [mm]
Typ. response behavior
y2
x
y1
Remarks
Adapter plate:
BT 3.2 (part no. 50103844)
for alternate mounting on
25.4mm hole spacing
(Omron E3Z, Sick W100…):
Mounting system:
=BT3
(part no. 50060511)
+ =BT3.1
1)
(part no. 50105585)
+ + =BT3B
(part no. 50105546)
1) Packaging unit: PU = 10 pcs.

RKR 3B Gloss