Datasheet

Leuze electronic
Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730
www.leuze.de
We reserve the right to make changes • 96_b14e.fm
z Polarised retro-reflective photoelectric
sensor with large operating range in visible
red light
z Robust metal housing with glass cover or
plastic housing, protection class IP 67 for
industrial application
z Complementary outputs for standard
applications and a wide range of input and
output variants for optimum adaptation to
the application
z Connection via M12 connector or terminal
compartment
z Multiple options with warning output, activa-
tion input, switching delays and optics
heating for use at low temperatures
10m
28m
10 - 30 V
DC
A
2
LS
Accessories:
(available separately)
z Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
z M12 connectors (KD …)
z Ready-made cables (K-D …)
z Reflectors
z Reflective tapes
U
L
US
C
LISTED
IEC 60947...
IEC 60947...
IP 67
Dimensioned drawing
A Indicator diode green
B Indicator diode yellow
C Receiver
D Transmitter
E Optical axis
F Device plug M12x1
G Screwed cable gland M 16x1.5 for Ø 5 10mm
H Countersinking for SK nut M5, 4.2 deep
I Connection terminals
K Cable entry
L Sensitivity adjustment
Electrical connection
PRK 96 Retro-reflective photoelectric sensors with polarisation filter
PRK 96 K/P… - 09