Datasheet
PRK 55/6(D).42… - 05 2012/11
Teach for 18% sensor sensitivity (standard bottles)
Press teach button until both LEDs flash
alternatingly
.
Release teach button.
Ready.
After the teaching, the sensor switches
when about 18% of the light beam are
covered by the object.
Teaching for maximum operating range (factory setting at delivery)
Prior to teaching:
Cover
the light path to the reflector!
Press teach button until both LEDs flash
simultaneously
.
Release teach button.
Ready.
Adjusting the switching behavior of the switching output – light/dark switching
Press teach button until the green LED flashes.
The yellow LED displays the current setting of
the switching output:
ON = output switches on light
OFF = output switches on dark
Continue to press the teach button in order to
change the switching behavior.
Release teach button.
Ready.
7…12s
alternatingly
flashing at
3Hz
LED
green
LED
yellow
2…7s
simultaneously
flashing at
3Hz
LED
green
LED
yellow
>12s
LED
green
flashes at
3Hz
LED yellow
ON =
light switching
OFF =
dark switching
PRK 55