Datasheet

ODSL 9/…-100-… - 03 2012/11
Specifications
Optical data
Measurement range
1)
1) Luminosity coefficient 6% 90%, complete measurement range, "Standard" operating mode, at 20°C,
medium range of U
B
, measurement object 50x50mm²
50 100mm
Resolution 0.01mm
Light source laser
Wavelength 655nm
Light spot divergent, 1x1mm
2
at 100mm
Laser warning notice see remarks
Error limits (relative to measurement distance)
Absolute measurement accuracy
1)
±0.5%
Repeatability
2)
2) Same object, identical environmental conditions, measurement object 50x50mm²
± 0.25%
B/W detection thresh. (6 90% rem.) 0.5%
Temperature compensation yes
3)
3) Typ. ± 0.02 %/K
Timing
Measurement time 2ms
Response time
1)
6ms
Delay before start-up 300ms
Electrical data
Operating voltage U
B
…C6/C66/V6/V66 18 30VDC (incl. residual ripple)
…D26/D36/66
10 30VDC (incl. residual ripple)
Residual ripple 15% of U
B
Open-circuit current 180mA
Switching output push-pull switching output
4)
,
PNP light switching, NPN dark switching
4) The push-pull switching outputs must not be connected in parallel
Signal voltage high/low (U
B
-2 V)/ 2V
Analog output …V6/V66 voltage 1…10V / 0…10V / 1…5V / 0…5V, R
L
2k
…C6/C66
current 4 20mA, R
L
500
Serial interface
…D26/D36 RS 232/RS 485, 9600 57600Bd,
1 start bit, 8 data bits, 1 stop bit, no parity
Transmission protocol 14 bit, 16 bit, ASCII, Remote Control
Indicators Teach-in on GND Teach-in on +U
B
Green LED continuous light ready
flashing fault teaching procedure
off no voltage
Yellow LED continuous light object inside teach-in measurement distance
flashing teaching procedure
off object outside teach-in measurement distance
Mechanical data
Housing plastic
Optics cover glass
Weight approx. 50g
Connection type M12 connector, 5-pin
Environmental data
Ambient temp. (operation/storage) -20°C +50°C / -30°C +70°C
Protective circuit
5)
5) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs
1, 2, 3
VDE safety class
6)
6) Rating voltage 50VAC
II, all-insulated
Protection class IP 67
Laser class 2 (according to EN 60825-1 and 21 CFR 1040.10
with Laser Notice No. 50)
Standards applied IEC 60947-5-2
Order guide
Designation Part No.
Analog current output
1 teachable push/pull output ODSL 9/C6-100-S12 50111167
2 push/pull outputs ODSL 9/C66-100-S12 50111171
Analog voltage output
1 teachable push/pull output ODSL 9/V6-100-S12 50111168
2 push/pull outputs ODSL 9/V66-100-S12 50111172
Serial digital output
RS 232, 1 push/pull output ODSL 9/D26-100-S12 50111169
RS 485, 1 push/pull output ODSL 9/D36-100-S12 50111170
Only switching outputs
2 teachable push/pull outputs ODSL 9/66-100-S12 50111173
Tables
Diagrams
ODSL 9
Remarks
Measurement time
depends on the reflectivity
of the measurement
object and on the
measurement mode.
Approved purpose:
This product may only be
used by qualified
personnel and must only
be used for the approved
purpose. This sensor is
not a safety sensor and is
not to be used for the
protection of persons.