Datasheet
ODS10L1.8/L⦠- 04 2016/08
IO-Link process data
Process data format: M-sequence TYPE_2_V
- PDOut (Master -> Sensor): none
- PDIn (Sensor -> Master): 24-bit (16 measurement value bits, 8 status bits)
Measurement values
16-bit measurement value: distance to the object ā between lower and upper limit of the measurement range ā in mm.
Special values:
- Signal=0 (no reception signal): 65535
- Measurement range exceeded: upper limit of the measurement range
- Measurement range below minimum value: lower limit of the measurement range
- Measurement=0 (while teaching or during activation): last measurement value
- Measurement=0 (during start-up): 65535
Status bits
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Bit 23 22 21 20 19 18 17 16
Value 0 0 W S M Q3 Q2 Q1
0 Unassigned bits (bit 22 and bit 23) are 0; initialization state is also 0
W 1: running measurement (measurement running)
0: during start-up, teaching, deactivation
S 1: signal OK, reception signal is sufficient for measurement value output
M 1: warning; e.g., weak reception signal
Q1 ⦠Q3 Switching states Q1, Q2, Q3
1: active
ODS10