Datasheet
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 ODS10L1.8/L… - 04
info@leuze.com • www.leuze.com
Laser safety notices
Analog output: characteristic curve for factory setting
Individual measure modes
ATTENTION, LASER RADIATION – LASER CLASS 1
The device satisfies the requirements of IEC 60825-1:2007 (EN 60825-1:2007) safety regulations for a product of laser class 1 as well
as the U.S. 21 CFR 1040.10 regulations with deviations corresponding to "Laser Notice No. 50" from June 24, 2007.
Observe the applicable statutory and local laser protection regulations.
The device must not be tampered with and must not be changed in any way.
There are no user-serviceable parts inside the device.
Repairs must only be performed by Leuze electronic GmbH + Co. KG.
Factory setting
A Area not defined
B Linearity not defined
C Measurement range
D Object present
E No object detected
F Measurement distance
Measure mode
Adjustable number of measurements
for the floating average calculation
Adjustable filter depth Measurement value formation
Individual 1 … 300 – –
Spike suppression 5 … 300
Raw
Approx. 75% of the
measurement values are
averaged in the center
Medium
Approx. 50% of the
measurement values are
averaged in the center
Fine
Approx. 25% of the
measurement values are
averaged in the center
300
ca. 2.5
4
20
ca. 24
I [mA]
0
1
10
ca. 11
U [V]
50 8000 8500 ca. 10000
75%
50%
25%
ODS10 Optical distance sensors