Technical data
Measurement data
Measurement range 50 3500mm (6 90% diffuse reflection)
50 8000mm (90% diffuse reflection)
Resolution 1mm
Accuracy ±15mm
1)
1) Typical values, measurement range 50 3500mm, diffuse reflectance 6% ... 90%, response time 50 ms,
“Standard” measure mode, at 20°C after warmup time of 20 min.
Reproducibility 0.5 2mm
2)
, see diagrams
2) Typical values, statistical value 1 sigma, diffuse reflectance 6% ... 90%, at 20°C after warmup time of 20 min.
Response time 3.4 1020ms, adjustable
3)
, see tables
3) Factory setting: “Standard” 50 ms
Output time 3.4ms
4)
, see tables
4) Factory setting, with filter functions adjustable from 17 1020ms
Temperature drift ±2mm/K
Optical data
Light source laser
Laser class 1 (acc. to IEC 60825-1:2007)
Wavelength 658nm (visible red light)
Impulse duration 6ns
Max. output power (peak) 391mW
Light spot approx. 7x7mm² at 8m
Timing
Measurement time “Fast” measure mode: 15 ms
“Standard” measure mode: 50 ms (factory setting)
“Precision” measure mode: 200 ms
“High precision” measure mode: 1000 ms
for individual measure modes, see Page 3
Readiness delay 300ms
Electrical data
Operating voltage U
B
5)
5) For UL applications: use is permitted exclusively in Class 2 circuits according to NEC
18 30VDC (incl. residual ripple)
Residual ripple 15% of U
B
Open-circuit current 150mA
Switching output push-pull switching output
6)
,
PNP light switching, NPN dark switching
6) The push-pull switching outputs must not be connected in parallel
Signal voltage high/low (U
B
-2V)/ 2V
Analog output ODS10L1.8/LA… voltage 1 10V / 0 10V / 1 5V / 0 5V, R
L
2kΩ
current 4 20mA, R
L
500Ω (factory setting)
IO-Link COM2 (38.4kBaud), vers. 1.1, min. cycle time 2.3ms,
SIO is supported
Indicators
Green/red LED Green continuous light ready
Red no signal
Orange warning, weak signal
Off no voltage
Yellow LEDs Q1/Q2 On object detected
Mechanical data
Housing plastic
Optics cover glass
Weight 70g (M 12 connector)
133g (2m cable)
90g (cable with M 12 connector)
Connection type turning M12 connector, 90°
2m cable, wire cross section 5 x 0.14mm² (5 x 26 AWG)
0.2m cable with M12 connector
Environmental data
Ambient temp. (operation/storage) -40°C +50°C/-40°C +70°C
Protective circuit
7)
7) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs
1, 2, 3
VDE safety class III
Degree of protection IP 67
Standards applied IEC 60947-5-2
Certifications UL 508, CSA C22.2 No.14-13
5)
8)
8) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.5A min,
in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)
Notes
You can download the IO Device Description (IODD file) and the Sensor Studio configuration
software (requires IO-Link USB master) from the Internet at www.leuze.com
.
Tables
Measure modes:
Measure mode Response time Output time
Fast 15ms 3.4ms
Standard 50ms 3.4ms
Precision 200ms 3.4ms
High precision 1000ms 3.4ms
Individual
1)
1) See “Individual measure modes” on
Page 3
3.4…1020ms 3.4ms
Spike
suppression
1)
17…1020ms 17…1020ms
Diagrams
A At 6% diffuse reflection
B At 90% diffuse reflection
2,0
3,0
4,0
2000 4000 6000 80000
A
B
Object distance [mm]
Typ. reproducibility [mm]
Typical reproducibility
Fast measure mode
1,0
2,0
3,0
2000 4000 6000 80000
A
B
Object distance [mm]
Typ. reproducibility [mm]
Typical reproducibility
Standard measure mode
Object distance [mm]
Typ. reproducibility [mm]
Typical reproducibility
Precision measure mode
Object distance [mm]
Typ. reproducibility [mm]
Typical reproducibility
High precision measure mode
ODS10
Notes
Observe intended use!
This product is not a safety sensor
and is not intended as personnel
protection.
The product may only be put into
operation by competent persons.
Only use the product in accor-
dance with its intended use.