Datasheet
Specifications for Leuze end devices
94 MA 248i Leuze electronic
16.7 LSIS 4x2i, DCR 202i (S4 switch position 7)
Specifications for the serial interface
Specifications for Command mode
To activate the Command mode, bit 0 must be set to 1 in control byte 0.
For further information, see chapter 11.1.3 "Command mode", figure 11.2.
Recommended settings
• Input module: dependent on the number of digits of the 2D code that is to be read.
With an 18-digit code (+ 2 bytes of status bytes), for example, the input module with
20 bytes is advisable.
• Output module: 4 bytes
Default parameter LSIS 4x2i, DCR 202i
Baud rate 9600
Data mode 8N1
Handshake no
Protocol framing protocol without acknowledgment
Frame <STX> <Data> <CR> <LF>
Control bit Meaning Corresponds to
serial command
(ASCII)
0 Version query v
1 Image acquisition trigger +
2
3
4
5
6
7
8
9
10
11
12
13
14
15