92 MA 248i Leuze electronic
16.5 Bar code reader BCL 90, BCL 900i (S4 switch position 5)
Specifications for the serial interface
Specifications for Command mode
To activate the Command mode, bit 0 must be set to 1 in control byte 0.
For further information, see chapter 11.1.3 "Command mode", figure 11.2.
Recommended settings
Input module: dependent on the number of digits of the bar code that is to be read.
With an 18-digit bar code (+ 2 bytes of status bytes), for example, the input module
with 20 bytes is advisable.
Output module: 4 bytes
Default parameter BCL 90, BCL 900i
Baud rate 9600
Data mode 8N1
Handshake no
Protocol framing protocol without acknowledgment
Frame <STX> <Data> <CR> <LF>
Control bit Meaning Corresponds to
serial command
(ASCII)
0 Version query v
1 Activation / deactivation reading gate + / -
2 Configuration mode 11
3 Alignment mode 12
4 Read operation 13
5
6
7
8
9
10
11
12
13
14 Reset parameters to default values PC20
15 Device restart H