Datasheet

Commissioning and configuration
Leuze electronic MA 248i 75
TNT 35/7-24V
12.4.4 Preparing the control system for consistent data transmission
During programming the control system must be prepared for consistent data transmission.
This varies from control system to control system.
Notice!
If an S7 control is used, you need to ensure that Simatic-Manager Version 5.4 + service
pack 5 (V5.4+SP5) or higher is used.
12.5 Variable configuration of the communication data width
The communication of the MA 248i with the fieldbus system can be configured with a vari-
able data width; the upper limit is restricted by the fieldbus. The following sizes are available
for the data frame for PROFINET-IO:
4 1024 bytes
Module Description Input data Output data
4 bytes input Data content with max. 2 bytes 4
8 bytes input Data content with max. 6 bytes 8
12 bytes input Data content with max. 10 bytes 12
16 bytes input Data content with max. 14 bytes 16
20 bytes input Data content with max. 18 bytes 20
32 bytes input Data content with max. 30 bytes 32
64 bytes input Data content with max. 62 bytes 64
128 bytes input Data content with max. 126 bytes 128
256 bytes input Data content with max. 254 bytes 256
384 bytes input Data content with max. 382 bytes 384
512 bytes input Data content with max. 510 bytes 512
640 bytes input Data content with max. 638 bytes 640
768 bytes input Data content with max. 766 bytes 768
896 bytes input Data content with max. 894 bytes 896
1024 bytes input Data content with max. 1022 bytes 1024
4 bytes output Data content with max. 2 bytes 4
8 bytes output Data content with max. 6 bytes 8
12 bytes output Data content with max. 10 bytes 12
16 bytes output Data content with max. 14 bytes 16
20 bytes output Data content with max. 18 bytes 20
32 bytes output Data content with max. 30 bytes 32
64 bytes output Data content with max. 62 bytes 64
128 bytes output Data content with max. 126 bytes 128
256 bytes output Data content with max. 254 bytes 256
384 bytes output Data content with max. 382 bytes 384
512 bytes output Data content with max. 510 bytes 512
640 bytes output Data content with max. 638 bytes 640
768 bytes output Data content with max. 766 bytes 768
896 bytes output Data content with max. 894 bytes 896
1024 bytes output Data content with max. 1022 bytes 1024
Table 12.2: Module overview