Datasheet

Configuration
Leuze electronic MA 248i 47
TNT 35/7-24V
Table 9.3: General gateway information
Table 9.4: Current states of the status and control bits
Table 9.5: ASCII configuration
Selected scanner Currently selected Leuze device (selected via switch S4).
Gateway mode Transparent or Collective mode.
Ring buffer fill level Current fill level of the ring memory in Collective mode (ASCII->Fieldbus).
1024 bytes max.
Received ASCII Frames Number of received ASCII frames.
ASCII Framing Error (GW) Number of received framing errors.
Number of Received CTB's Number of CTB commands.
Number of Received SFB's Number of SFB commands.
Command-Buffer fill level Current fill level of the ring memory in Command mode (fieldbus->ASCII).
1024 bytes max.
Number of received transparent frames Number of received fieldbus frames without CTB/SFB.
Number of send fieldbus frames Number of frames sent via the fieldbus.
Number of invalid commands Number of invalid commands.
Number of ASCII stack send errors Number of frames that the ASCII memory could not send.
Number of good ASCII send frames Number of frames that the ASCII memory sent successfully.
ND Current status of ND bit.
W-Ack Current status of W-Ack bit.
R-Ack Current status R-Ack bit.
Data loss Current status of data loss bit.
Ring buffer overflow Current status of ring buffer overflow bit.
DEX Current status of DEX bit.
BLR Current status of BLR bit.
ASCII-Start-Byte Currently configured start byte
(dependent on switch position S4).
ASCII-End-Byte1 Currently configured stop byte 1
(dependent on switch position S4).
ASCII-End-Byte2 Currently configured stop byte 2
(dependent on switch position S4).
ASCII baud rate Currently configured baud rate
(dependent on switch position S4).
ASCII warm start status Indicates whether the ASCII memory has detected and accepted a valid
configuration.