Datasheet

LS 96 K/R… - 11 2014/06
LS 96 M/R … - 11
Specifications
Optical data 65m 150m
Typ. operating range limit
1)
1) Typ. operating range limit: max. attainable range without performance reserve
0…65m 0…150m
Operating range
2)
2) Operating range: recommended range with performance reserve
0 … 50m 0 … 120m
Light source LED (modulated light)
Wavelength 880nm (infrared)
Timing
Switching frequency 20Hz
Response time 25ms
Delay before start-up 200ms
Electrical data
Operating voltage U
B
20 230VAC, 50/60Hz
20 … 230VDC
Power consumption 1.5VA
Switching output
3)
3) Suitable spark extinction must be provided with inductive or capacitive loads
relay, 1 change-over contact
Function characteristics break-contact/make-contact
Switching voltage, relay 250VAC/DC
Switching current, relay 250VAC, 3A/30V, 3A
Open-circuit current 750VA, cosϕ=1
Sensitivity adjustable
Indicators
Green LED ready
Yellow LED light path free
Yellow LED, flashing light path free, no performance reserve
Mechanical data Metal housing Plastic housing
Housing diecast zinc polycarbonate
Optics cover glass plastic
Weight 380g 150g
Connection type terminals terminals
Environmental data
Ambient temp. (operation/storage) -3C +6C/-4C +7C
Protective circuit
4)
4) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs
1, 2, 3
VDE safety class
5)
5) Rating voltage 250VAC
II, all-insulated
Protection class IP 67, IP 69K
6)
6) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,
acids and bases are not part of the test
IP 67
Light source exempt group (in acc. with EN 62471)
Standards applied IEC 60947-5-2
Certifications
7)
7) LS 96M/R-1310-2, LS 96M/R-3310-2
UL 508, C22.2 No.14-13
Options
Switching delay (slow oper./release) 0 … 10s (separately adjustable)
Operate in accordance with intended use!
This product is not a safety sensor and is not intended as personnel protection.
The product may only be put into operation by competent persons.
Only use the product in accordance with the intended use.
Order guide
Selection table
Order code
Equipment
LS 96K/R-1310-2
Part No. 50025253 (Tr)
Part No. 50025257 (Re)
LS 96K/R-1320-2
Part No. 50025253 (Tr)
Part No. 50025256 (Re)
LS 96M/R-1310-2
Part No. 50080081 (Tr)
Part No. 50080080 (Re)
LS 96M/R-3310-2
Part No. 50080081 (Tr)
Part No. 50031651 (Re)
LS 96K/R-131P-2
Part No. 50030405 (Tr)
Part No. 50030406 (Re)
Housing metal 
plastic 
Light source infrared light (50m) 
infrared light (120m)
Connection terminals 
Features switching delay
UL homologation 
Tables
65m models
150m models
05065
0 120 150
Operating range [m]
Typ. operating range limit [m]
Remarks
LS 96K/R-131P-2
P = Reduction M16
LS 96K/R-1310-2
LSS 96K-1350-26
LSE 96K/R-1310-25
LS 96K/R-1320-2
LSS 96K-1350-26
LSE 96K/R-1320-25
LS 96M/R-1310-2
LSS 96M-1350-26
LSE 96M/R-1310-25
LS 96M/R-3310-2
LSS 96M-1350-26
LSE 96M/R-3310-25
LS 96K/R-131P-2
LSS 96K-135P-26
LSE 96K/R-131P-25
LS = Pair consisting of
LSS = Transmitter
LSE = Receiver
LS 96
Diagrams
65m models
150m models
-1,0
-0,8
-0,6
-0,4
-0,2
0
0,2
0,4
0,6
0,8
1,0
0 102030405060
70
y1
y2
Distance x [m]
Misalignment y [m]
Typ. response behaviour
-3,5
-2,5
-1,5
-0,5
0,5
0
1,5
2,5
3,5
0 20 40 60 80 100 120 140
160
y1
y2
Distance x [m]
Misalignment y [m]
Typ. response behaviour
y2
y1
x