Datasheet

Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 GS 61… - 07
info@leuze.de • www.leuze.com
Type key
Sensor adjustment via potentiometer for GS 61
Notice: A removable operating head is plugged on the potentiometer in ex works. This can be used
to manually adjust the forked photoelectric sensor without the use of a tool. If this is not desired,
the operating head can be pulled off – a screwdriver is then necessary for making adjustments.
The following description applies to a forked photoelectric sensor with switching signal in the label
gap (GS 61/6…). For device versions with switching signal on the label (GS 61/6D…), the LED indi-
cators are inverted.
Preparation: Remove one or more labels from the base material and advance this blank area into
the sensor.
- If the yellow OUT LED does not switch on when the blank area is encountered, increase the
sensitivity by turning the potentiometer clockwise until the yellow OUT LED switches on.
- Starting from this setting, turn the potentiometer clockwise another approx. one half turn.
- Now advance the label tape so that a label is in the sensor.
- If set correctly, the yellow OUT LED must now switch off. Reduce the sensitivity by turning
counterclockwise if the LED remains on.
- Finished: if set correctly, the LED changes between gap and label.
GS 61/ 6D. 2-S8V. 3
Operating principle
GS Forked sensor, optical
Series
61 Small series with excellent price / performance ratio
Output function
/6 Push-pull output: PNP signal in the label gap, NPN signal on the label
/6D Push-pull output: PNP signal on the label, NPN signal in the label gap
Configuration
N/A Potentiometer adjustment
.2 Teach button on the device
.3 Teach button on the device and teach input
Electrical connection
N/A Device with cable, standard length 2000mm, cable outlet at 45°
-S8 M8 connector, 4-pin, horizontal plug outlet
-S8V M8 connector, 4-pin, vertical plug outlet
-S8.3 M8 connector, 3-pin, horizontal plug outlet
-S8V.3 M8 connector, 3-pin, vertical plug outlet
,200-S12 200mm cable with M12 connector, 5-pin, cable outlet at 45°
Top view of sensor with
operating head plugged.
Detach operating head;
use screwdriver if
necessary.
GS 61 Forked photoelectric sensor