Datasheet

ET 318B… - 03 2015/09
Specifications
Optical data
Scanning range limit
1)
1) Scanning range limit: typical scanning range
axial optics: 1 1000mm
90° optics: 5 450mm
Scanning range
2)
2) Scanning range: ensured scanning range
see tables
Light source LED (modulated light)
Wavelength 620nm (visible red light)
Timing
Switching frequency 500Hz
Response time 1ms
Delay before start-up 300ms
Electrical data
Operating voltage U
B
3)
3) For UL applications: for use in class 2 circuits according to NEC only
10 30VDC (incl. residual ripple)
Residual ripple 15% of U
B
Open-circuit current 20mA
Switching output …/4P…
2 PNP transistor outputs
pin 2: PNP dark switching, pin 4: PNP light switching
…/2N…
2 NPN transistor outputs
pin 2: NPN dark switching, pin 4: NPN light switching
Signal voltage high/low (U
B
-2.5V)/ 2.5V
Output current max. 100mA
4)
4) Sum of the output currents for both outputs, 50mA when ambient temperatures > 40°C
Indicators
Green LED ready
Yellow LED reflection (object detected)
Mechanical data
Housing plastic
Optics cover plastic
Weight 20g with M12 connector
70g with 2m cable
Connection type M12 connector, 4-pin
cable 2m, 4x0.20mm²
Environmental data
Ambient temp. (operation/storage) -40°C +60°C/-40°C +70°C
Protective circuit
5)
5) 2=polarity reversal protection, 3=short circuit protection for all outputs
2, 3
VDE safety class III
Degree of protection IP 67
Light source exempt group (in acc. with EN 62471)
Standards applied IEC 60947-5-2
Certifications UL 508, C22.2 No.14-13
3)
6)
6) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.5A min,
in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)
Tables
Axial optics:
90° optics:
1 1 700 1000
2 1 590 850
3 3 390 550
4 5 280 400
1 5 350 450
2 10 290 380
3 12 190 250
4 15 140 200
1 white 90%
2 gray 50 %
3 gray 18 %
4 black 6 %
Scanning range [mm]
Typ. scanning range limit [mm]
Diagrams
Axial optics:
90° optics:
A white 90%
B gray 50%
C gray 18%
D black 6%
0
100
200
300
400
700
600
500
0 200 400 600 800 1000
A
B
C
D
Scanning range x [mm]
Red. of scan range y [mm]
Typ. black/white behavior
0
50
100
150
200
300
250
0 100 200 300 400
50 150 250 350 450
A
B
C
D
Scanning range x [mm]
Red. of scan range y [mm]
Typ. black/white behavior
x
y
Remarks
With the set scanning
range, a tolerance of the
scanning range limits is
possible depending on the
reflection properties of the
material surface.
Operate in accordance with
intended use!
This product is not a safety sensor
and is not intended as personnel
protection.
The product may only be put into
operation by competent persons.
Only use the product in accor-
dance with the intended use.
ET 318B