Manual
20
VX-II and Vari-X III models have a pointer dial that moves with the
adjustment slot. This dial also can be moved independently to align with the
zero on the outermost dial. To reposition this dial simply rotate it until the
pointer is aligned with the zero.
To reposition the dials on Target and Tactical models:
1.
Loosen the set screws that surround the top of the knob until the cylinder
turns freely.
2.
Move the cylinder dial by hand to align the zero with the white
perpendicular mark at the base of the cylinder.
3.
Tighten the set screws until the cylinder is secure.
Target-style dials
can be adjusted
to the new zero
position by
loosening the
set screws, rotating the dial,
and tightening the set screws.
VX-ll and
Vari-X III dials
have a separate
pointer dial
that can be
adjusted to indicate the
new zero position.