Manual

[
M
aking precise windage
and elevation adjustments
]
16
The style of elevation and windage adjustments on Leupold scopes varies
with specific models. If you are unsure of the value of your scope’s adjustment
increments, follow these steps.
Determining the value of adjustment increments:
1.
Count the number of hash marks—from zero to and including that of
the first number—on the dial.
2.
Divide the first number on the dial by the number of hash marks counted.
For example, divide 1 (the first number on the dial to which you counted)
by 4 (the number of hash marks counted) to get .25 or 1/4.
The resulting number is the value of each increment of adjustment in
MOA. This method will work with any Leupold adjustment dial. One MOA
moves the point-of-impact at 100 yards by one inch (at 100 meters,
it moves 29mm).