If the reticle is installed in the second focal plane of an optic, it is calibrated to
a specific magnification for range estimating purposes. In a variable-magnifi-
cation scope, this is generally the highest magnification setting and all range
estimating must be performed at this setting. However, in certain scopes it may
be calibrated for a different setting. If you are uncertain as to what setting
your scope is calibrated, contact Leupold Technical Service at 1-800-Leupold
(1-800-538-7653).
THE USE OF A MIL DOT OR TMR RETICLE
To use the Mil Dot or TMR reticle, you must know the actual size of
the target.
1. View the target through the scope.
2. Place the center of the crosshair against one edge (top, bottom, or
either side) of the target so that the crosshair extends along either
its width or height.
3. Using the dots or hash marks, measure along the crosshair to the
opposite edge of the target.
If the center of the crosshair is against one edge of the target and
the opposite edge of the target is positioned behind the center of
the second mil mark, the target measures 2 mils. If it is exactly