Installation Guide
www.lesscare.com
ULTRA-C
SHOWER ENCLOSURES
INSTALLATION STEPS
8
Figure 2
2. Your Upper Guide Rail (4) has been precut for your 
Shower model opening width: 48" or 60" for shower width. 
If W-width of your wall-to-wall opening is equal to the size 
of your Shower model, it is unnecessary to cut the Upper 
Guide Rail and you can continue to Step 3. If W-width of 
your wall-to-wall opening is less than the size of your 
Shower model, you will need to cut the Upper Guide Rail 
from the end which is farther from the Glass brackets (18).
The length to cut off will be L:
L=Subtract W from the size of your Shower
model.
Remark: With the Return Panel Installed, you need to cut 
the roller bar 1/2” at least.
See Fig. 2 for details.
FOR EXAMPLE
If your wall opening W=47”. Your shower
model is 48”.
L=48”-47”=1”,
You have to cut 1” off from the rail.
d.
c.
a.
b.
3
3
Note: The Glass Bracket (18) has been pre-installed to the Upper Guide Rail (4).
Attention: Please cut the guide rail from this side, which is farther 
side from the hole of the guide rail bracket.
27
27
4
4
18
18
2
2