Submittal Sheet

1360 Elmwood Avenue, Cranston, RI 02910 USA
Phone: 401.461.1200 Fax: 401.941.5310
Email: info@leonardvalve.com
Web Site: http://www.leonardvalve.com
© 2019 Leonard Valve Company
Printed in USA
Engineer's Approval Job # ____________________
Arch/Eng. ________________
Contractor ________________
CAUTION! All thermostatic water mixing valves have limitations. They will
NOT provide the desired accuracy outside of their flow capacity range. Consult
the Flow Capacity Chart and DO NOT OVERSIZE. Minimum flow must be no
less than as indicated.
NOTE: Flow rates will vary depending on existing field conditions.
Leonard Valve Company always recommends using CASPAK®
sizing software for proper valve sizing and model number
applications.
Note: The models shown represent Leonard Products which are believed to be
equivalent in type and function to items specified. Leonard Valve Company is
not responsible for errors or omissions due to differences in interpretations of
information provided.
Note: Leonard Valve Company reserves the right of product, or
design modifications without notice or obligation.
MINIMUM
(l/min)
(GPM)
FLOW
0.25**
163
43
2.4
35
170
45
2.8
40
182
48
3.1
45
193
51
3.4
50
(0.95)**
PRESSURE DROP
10664 95
10
25
.7
17
.3
5
28
.97
15
121
32
1.4
20
l/min
136 148
36 39
1.7
25
2.1
30
GPM
PSI