Fault messages
DFIN (MXI1): Track error A-/A [0x00990000]
DFIN (MXI1): Track error B-/B [0x00990001]
DFIN (MXI1): Track error Z-/Z [0x00990002]
DFIN (MXI1): Signal error enable/lamp control [0x00990003]
DFIN (MXI1): Supply cannot be corrected anymore [0x00990004]
DFOUT (MXI1): Maximum frequency reached [0x00990005]
Response (Lenze setting in bold) Setting: C13040 (; Adjustable response)
; No System fault : Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
Digital frequency extension module in MXI1:
Interruption (open circuit) of signal cable for track A.
• Check signal cable for track A.
•Check encoder.
Response (Lenze setting in bold) Setting: C13040 (; Adjustable response)
; No System fault : Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
Digital frequency extension module in MXI1:
Interruption (open circuit) of signal cable for track B.
• Check signal cable for track B.
•Check encoder.
Response (Lenze setting in bold) Setting: C13040 (; Adjustable response)
; No System fault : Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
Digital frequency extension module in MXI1:
Interruption (open circuit) of signal cable for track Z.
• Check signal cable for track Z.
•Check encoder.
Response (Lenze setting in bold) Setting: C13041 (; Adjustable response)
; No System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked : Warning ; Information
Cause Remedy
Digital frequency extension module in MXI1:
Interruption (open circuit) of signal cable for "Enable"
signal or no "Enable" signal available.
• Check signal cable for "Enable" signal.
•Check encoder.
Response (Lenze setting in bold) Setting: C13042 (; Adjustable response)
; No System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked : Warning ; Information
Cause Remedy
Digital frequency extension module in MXI1: The
encoder voltage controlled by the digital frequency input
has reached the voltage limit.
Check encoder.
Response (Lenze setting in bold) Setting: C13080 (; Adjustable response)
; No System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked : Warning ; Information
Cause Remedy
Digital frequency extension module in MXI1: Limit
frequency at the digital frequency output reached.
• The digital frequency has reached the limit value set
in C013053
.
Check set limit value.