User Manual

EDS94AYFLF EN 3.2 - 10/2010 L 45
Digital frequency extension module | Parameter setting & configuration
Parameter reference
Table of attributes
4.2 Table of attributes
The table of attributes contains information required for communicating with the
controller via parameters.
How to read the table of attributes:
Column Meaning Entry
Code Parameter designation Cxxxxx
Name Short parameter text (display text) Text
Index dec Index under which the parameter is addressed.
The subindex of array variables corresponds to the
Lenze subcode number.
24575 - Lenze code number Only required for access via bus
system.
hex 5FFF
h
- Lenze code number
Data DS Data structure E Single variable
(only one parameter element)
A Array variable
(several parameter elements)
DA Number of array elements (subcodes) Number
DT Data type BITFIELD_8 1 byte bit-coded
BITFIELD_16 2 bytes bit-coded
BITFIELD_32 4 bytes bit-coded
INTEGER_8 1 byte with sign
INTEGER_16 2 bytes with sign
INTEGER_32 4 bytes with sign
UNSIGNED_8 1 byte without sign
UNSIGNED_16 2 bytes without sign
UNSIGNED_32 4 bytes without sign
VISIBLE_STRING ASCII string
Factor Factor for data transmission via bus system,
depending on the number of decimal positions.
Factor 1 no decimal positions
10 1 decimal position
100 2 decimal positions
1000 3 decimal positions
Access R Read access ; Reading allowed
W Write access ; Writing allowed
CINH Controller inhibit required ; Writing only possible when controller is inhibited