User Manual
9400 Technology applications | Positioning sequence control
Parameter setting & configuration
Parameterisable function blocks
74 L EDS94TA10060xxxx EN 1.2 - 03/2010
5.14.12 MonitFollowError1
5.14.13 MonitFollowError2
C03915 String of digits Position unit
•Read only
C03916 -2147483647 2147483647 State
•Read only
Parameter Possible settings Information
Is an instance of Function
L_LdMonitFollowError Following error monitoring
( 54)
Parameter Possible settings Information
C03960 -214748.3647 unit 214748.3647 Following error at the input
• Display of the input signal
dnFollowErrorIn_p in the real unit
of the machine.
C03961 String of digits Position unit
•Read only
C03963 Following error out of tolerance
•Read only
FALSE Following error smaller than set
switching threshold
TRUE Following error larger than set
switching threshold
C03964 Following error monitoring activated
•Read only
FALSE Deactivated
TRUE Activated
Is an instance of Function
L_LdMonitFollowError Following error monitoring
( 54)
Parameter Possible settings Information
C03965 -214748.3647 unit 214748.3647 Following error at the input
• Display of the input signal
dnFollowErrorIn_p in the real unit
of the machine.
C03966 String of digits Position unit
•Read only
C03968 Following error out of tolerance
•Read only
FALSE Following error smaller than set
switching threshold
TRUE Following error larger than set
switching threshold
C03969 Following error monitoring activated
•Read only
FALSE Deactivated
TRUE Activated