5.14.9 L_SdSwitchPoint1
5.14.10 LimitFollowingError1
5.14.11 LimitFollowingError2
Is an instance of Function
L_SdSwitchPoint Position switch points (cams)
Parameter Possible settings Information
C04395/1...8 State of switching range 1 ... 8
•Read only
0Switch is off
1Switch is on
C04396 String of digits Position unit
•Read only
C04397/1...8 -2147483648 unit 2147483648 Switch-on position switching range
1 ... 8
C04398/1...8 -2147483648 unit 2147483648 Switch-off position switching range
1 ... 8
C04399/1...8 Enable switching range 1 ... 8
0 Switching range not enabled
1 Switching range enabled
Is an instance of Function
L_SdSetPosition Conversion of the following error switching threshold 1 selected in the real units of
the machine via C03911 into a position in [increments].
Following error monitoring
( 54)
Parameter Possible settings Information
C03911 -214000.0000 unit 214000.0000 Position value
• Initialisation: 100.0000 unit
C03912 String of digits Position unit
•Read only
C03913 -2147483647 2147483647 State
•Read only
Is an instance of Function
L_SdSetPosition Conversion of the following error switching threshold 2 selected in the real units of
the machine via C03914 into a position in [increments].
Following error monitoring
( 54)
Parameter Possible settings Information
C03914 -214000.0000 unit 214000.0000 Position value
• Initialisation: 200.0000 unit