9400 Technology applications | Positioning sequence control
Parameter setting & configuration
Application error messages
5.13 Application error messages
For the output of application-specific error messages, the FB instances ApplicationError1
and ApplicationError2 of the function block L_DevApplErr are available in the network.
Via the boolean inputs up to 16 different application error messages with
parameterisable module ID, error ID and error response can be released by the
application.
Parameter setting: Tab All parameters
Reset of error message
In the Lenze setting the digital input DI5 for resetting (acknowledging) an error message is
connected to the input DI_bResetError1 of the drive interface.
Error message Error ID Error response
FB instance "ApplicationError1"
1 Following error limit 1 8001 Warning
2 Following error limit 2 8002 Warning locked
3 Positioner: Home position is not known 8003 Warning
4 Positioner: Cycle is not known 8004 Warning
5 Positioner: Wrong positioning mode 8005 Warning
6 Positioner: Invalid change of the positioning mode 8006 Warning
7 Positioner: Profile data is not plausible or faulty 8007 Warning
8 Positioner: Error in profile generation 8008 Warning
FB instance "ApplicationError2"
1 Free error message 1 8011 Information
2 Free fault message 2 8012 Information
3 PositionerTable: Invalid axis data structure 8013 Warning
4 PositionerTable: Invalid profile no. 8014 Information
5 PositionerTable: Invalid table no. 8015 Warning
6 Watch-Dog 8016 Quick stop by trouble
7 Sequencer: Error due to variable branch 8017 Warning
8 Sequencer: Pause 8018 Information
Parameter Lenze setting
FB instance "ApplicationError1"
C05900 Function block ID 999
C05901/1...8 Error ID 1 ... 8 See table above
C05902/1...8 Error response 1 ... 8 See table above
FB instance "ApplicationError2"
C05903 Function block ID 998
C05904/1...8 Error ID 1 ... 8 See table above
C05905/1...8 Error response 1 ... 8 See table above