User Manual

EDS94TA10060xxxx EN 1.2 - 03/2010 L 61
9400 Technology applications | Positioning sequence control
Parameter setting & configuration
Signal configuration
5.11 Signal configuration
5.11.1 Drive and motor interface
If required, the preset signal configuration of the control and setpoint inputs of the drive
and motor interface can be easily reconfigured by parameterising the assigned multiplexer
parameters.
Drive interface
Motor interface
Signal (Lenze setting) Control input Signal configuration
FALSE Set controller inhibit C03130/1
DIGIN 5 Reset error 1 C03130/2
FALSE Reset error 2 C03130/3
FALSE Reset error 3 C03130/4
FALSE Set error C03130/5
FALSE Switch on drive C03130/6
Signal (Lenze setting) Setpoint input Signal configuration
100 % Position controller adaptation C03141/1
100 % Phase controller adaptation C03141/2
100 % Speed controller adaptation C03141/3
100 % Upper torque limit value C03141/4
-100 % Lower torque limit value C03141/5
100 % Flux setpoint C03141/6
100 % Adaptation of mass inertia C03141/7