User Manual
9400 Technology applications | Positioning sequence control
Parameter setting & configuration
Limiter
58 L EDS94TA10060xxxx EN 1.2 - 03/2010
For manual jog only
C02713 Max. manual jog distance 360.0000 unit
Limited speed 1 ... 4 (only for homing, positioning, and manual jog)
C02708/1 Limited speed 1 3600.0000 unit/s
C02710/1 Delay lim. speed 1 0.0100 unit/s
2
C02711/1 S-ramp time lim. speed 1 100 ms
C02708/2 Limited speed 2 7200.0000 unit/s
C02710/2 Delay lim. speed 2 0.0100 unit/s
2
C02711/2 S-ramp time lim. speed 2 100 ms
C02708/3 Limited speed 3 14400.0000 unit/s
C02710/3 Delay lim. speed 3 0.0100 unit/s
2
C02711/3 S-ramp time lim. speed 3 100 ms
C02708/4 Limited speed 4 28800.0000 unit/s
C02710/4 Delay lim. speed 4 0.0100 unit/s
2
C02711/4 S-ramp time lim. speed 4 100 ms
Control inputs of the function Signal configuration
Lenze setting Control input (Multiplexer parameters)
DIGIN 3 Positive limit switch C03150/1
DIGIN 4 Negative limit switch C03150/2
Parameter Lenze setting
Value Unit