User Manual
EDS94TA10060xxxx EN 1.2 - 03/2010 L 41
9400 Technology applications | Positioning sequence control
Parameter setting & configuration
Program flow
5.3.6 Sequencer outputs
Via a DWORD-to-BIT-converter, 32 sequencer outputs of type "BOOL" are available for
"switching" which can be set to FALSE or TRUE with the action type "switching".
These sequencer outputs can be connected with the inputs of the application or device
interfaces via multiplexer parameters.
The following table lists the corresponding module outputs of the FB interconnection
and the corresponding selection numbers for the multiplexer parameters:
Module output Signal type Selection no. Selection text
SequencerOutput.bBit0 551 Sequencer output 1
SequencerOutput.bBit1 552 Sequencer output 2
SequencerOutput.bBit2 553 Sequencer output 3
... ... ...
SequencerOutput.bBit31 582 Sequencer output 32